High efficiency, Performance guide specifications, System life / warranty – Sylvania QUICKTRONIC T8 User Manual

Page 4: Powersense

Advertising
background image

Output Wiring: Lamp wiring for dimming ballasts can differ significantly from non-dimming
ballasts and from other manufacturers dimming ballasts. Take care to connect lamp lead wires as

shown on the applicable ballast diagram. Lamp Seasoning: For optimal performance, fluorescent lamps may require seasoning for up to 12
hours prior to low temperature starting & low level dimming. Refer to NEMA LSD 23-2002 Lighting Systems Division: Recommended Practice —
Lamp Seasoning for Fluorescent Dimming Systems

Installation Notes

POWERSENSE

T8 DIM

Control Information

Catalog #

Date

Type

Project

Prepared by

Comments

SPECIFICATION DATA

Starting Method: Programmed Rapid Start

Circuit Type: Series

Lamp Frequency: >40 kHz

Lamp CCF: Less than 1.7

Starting Temp: 50°F/10°C minimum

for OCTRON T8 lamps

Input Voltage: 120-277V, ±10%

Input Frequency: 50/60 Hz

THD: <10% @ Full Output

Power Factor: >98% @ Full Output

UL Listed Class P, Type 1 Outdoor

CSA or C/UL Certified

70°C Max Case Temperature

FCC 47CFR Part 18 Non-Consumer

Class A Sound Rating

ANSI C62.41 Cat. A Transient Protection

Remote mounting (Max. wire length from

ballast case to lampholder) up to 8 feet

Performance Guide

Specifications

Data based on F32T8

High Efficiency

Electronic T8 Fluorescent Controllable Lighting Systems

Input

Input

Rated

Ballast

Initial

Input

System

Item

Voltage

Current

Lamp

Lumens

No. of

Factor

System

Power

Efficacy

Number

Description

(VAC)

(AMPS)

Type

(lm)

Lamps

(BF)

Lumens

(Watts)

(lm/W)

BEF

1

50705

QTP 1x32T8/UNV DIM-TC

120-277

0.27/0.12

FO32XP

3000

1

0.88

2640

30

88

2.93

0.05

150 8

50707

QTP 2x32T8/UNV DIM-TC

120-277

0.54/0.24

FO32XP

3000

2

0.88

5280

59/57

89/93

1.54

0.05

300 14

50714

QTP 3x32T8/UNV DIM-TCL 120-277

0.73/0.30

FO32XP

3000

3

0.88

7920

87/84

91/94

1.05

0.05 450 20

50716

QTP 4x32T8/UNV DIM-TCL 120-277

0.96/0.40

FO32XP

3000

4

0.88

10560

114/110

92/96

0.80

0.05

600 27

Products are all 10-pack. 1: Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (note: calculation based on lowest wattage value)

Item Number

50707 QTP 2 x 32T8 / UNV DIM-TC

QUICKTRONIC PROFESSIONAL

Number of Lamps (1, 2, 3, 4)

System Type - DIMMING/Case Size

Line Voltage (120-277V)

Primary Lamp Wattage

System Life / Warranty

QUICKTRONIC products are covered by QUICK

60+

®

, a comprehensive lamp and ballast

system warranty. For additional details, refer

to the QUICK 60+ warranty bulletin.

Data based on SYLVANIA OCTRON

®

lamps

shown. QUICKTRONIC

®

POWERSENSE

ballasts are also compatible with other

manufacturers equivalent lamp types that

meet ANSI specifications, including F17,

F25, F32 and the U-Bend equivalent lamps.

T8

POWERSENSE

®

High Efficiency

OSRAM SYLVANIA
National Customer
Service and Sales Center
1-800-LIGHTBULB
(1-800-544-4828)
www.sylvania.com

Black

White

Violet (+)

Grey (-)

Red
Red

Blue
Blue

LAMP 1

ELECTRONIC

BALLAST

BALLAST

ELECTRONIC

LAMP 1

LAMP 4

LAMP 3

LAMP 2

Yellow/Black

Yellow

Yellow

Red/Black

Red/White

Red

Red/White

Blue

Blue/White

Blue/White

Blue/Black

Grey (-)

Black
White

Violet (+)

Black

White

Violet (+)
Grey (-)

Red
Red

Blue
Blue

LAMP

1

Yel/Blk

Yellow
Yellow

LAMP 1

ELECTRONIC

BALLAST

LAMP 2

Dimensions:

1 & 2 lamp enclosure

Overall: 9.5" L x 1.68" W x 1.0" H (241 x 43 x 25 mm)

Mounting: 8.90" (226 mm)

Weight: 1.1 lbs each (500 g)

3 & 4 lamp enclosure

Overall: 16.7" L x 1.68" W x 1.0" H (425 x 43 x 25 mm)

Mounting:16.2" (411 mm)

Weight: 2.1 lbs each (950 g)

Wiring:

Leads Only

Mounting

Length

Length

Height

8.70 mm

Slot

Width

Yel/Blk

Yellow

Yellow

Red/Black

Red/White

Red

Red/White

Blue

LAMP 1

LAMP 3

ELECTRONIC

BALLAST

Black

White

Violet (+)

Grey (-)

LAMP 2

Input & Control
Wiring Options:

POWERLINE CONTROL

LINE

BLACK

NEUTRAL

WHITE

INSULATE
UNUSED LEADS

VIOLET (+)

GREY

(-)

1 lamp

2 lamp

3 lamp

4 lamp

LOW-VOLTAGE CONTROL

VIOLET (+)

GREY

(-)

LINE

BLACK

NEUTRAL

WHITE

0-10V

DC

< 0.5

m

A

Class 1 or
Class 2

QUICKTRONIC POWERSENSE ballasts are

compatible with a wide range of low voltage (0-

10VDC) and power line fluorescent controllers

available from various manufacturers.

Low Voltage Control Specs: Ballast will source

up to 0.5mA for 0-10VDC control purposes.

May be wired as a Class 1 or Class 2 circuit-

consult Local and National Electrical Codes.

Power Line Control Specs: Specification-

grade fluorescent controls are available for

120V or 277V operation of controllable

analog electronic fluorescent ballasts.

Controls must be suitably rated for both the

type (e.g. Fluorescent Phasecontrol) and size

(e.g. 600W) of the connected load.

SYLVANIA, the system solution, QUICK60+, POWERSENSE, See the World in a New Light and PROStart are registered trademarks of OSRAM SYLVANIA Inc.

ELOGIC is a trademark of OSRAM SYLVANIA Inc. QUICKTRONIC is a registered trademark of OSRAM GmbH. NEMA Premium is a registered trademark of National Electrical Manufacturers Association.

©2010 OSRAM

SYL

V

ANIA

Specifications subject to change without notice.

Height
25.4mm
(1.0")

Mounting
411.3mm
(16.2")

Length
425mm
(16.7")

Width
43mm
(1.68")

Advertising