Good read led, Start/end program menu, Diagnostics – Opticon OPT-6125 User Manual

Page 59

Advertising
background image

Manual No. 25-ULGPMU01-01 Series OPT Handheld
CCD Scanner

Page 59

Quiet Zone Settings

ZZ

Start/End

Program

Menu

-[[-

YN

No margin

check

-ZO-

YO

Margin

check 1/7

normal

-ZP-

YP

Margin

check 2/7

normal

-ZQ-

YQ

Margin

check 3/7

normal

-ZR-

YR

Margin

check 4/7

normal

-ZS-

YS

Margin

check 5/7

normal

-ZE-

YT

Margin

check 6/7

normal

-ZU-

YU

Margin

check

normal

-ZV- %

With these settings, the reader can decode bar codes that have smaller start and/or end margins than specified for the
symbology. These settings may increase the possibility of partial and ghost reads, hence do not use smaller margin
checks than necessary. Replace any bar code labels with ones that have the correct start and end margins if possible.

Advertising