SUUNTO D4 User Manual

Page 84

Advertising
background image

Tissue calculation model:
•

Suunto Deep Stop RGBM algorithm (developed by Suunto and Bruce R. Wienke,
BSc, MSc, PhD)

•

9 tissue compartments

•

Tissue compartment halftimes: 2.5, 5, 10, 20, 40, 80, 120, 240 and 480 minutes
(on gassing). The off gassing halftimes are slowed down

•

Reduced gradient (variable) "M" values based on diving habit and dive violations.
The "M" values are tracked up to 100 hours after a dive

•

The EAN and oxygen exposure calculations are based on recommendations by
R.W. Hamilton, PhD and currently accepted exposure time limit tables and principles

Battery:
•

One 3 V lithium battery: CR 2450

•

Battery storage time (shelf life): Up to three years

•

Replacement: Every two years, or more often depending on dive activity

•

Life expectancy at 20°C/68°F:
•

0 dives/y –> 2 years

•

100 dives/year –>1,5 years

•

300 dives/year –>1 year

The following conditions have an effect on the expected battery lifetime:
•

The length of the dives

•

The conditions in which the unit is operated and stored (e.g. temperature/cold
conditions). Below 10°C/50°F the expected battery lifetime is about 50-75% of that
at 20°C/68°F

•

The use of the backlight and audible alarms

85

Advertising