D M D - 4 8 0 - S 2 S E R I E S A C P O W E R E D B R I D G E S E N S O R - R S 2 3 2 I N T E R F A C E

4

PHONE:(203)359-1660 FAX:(203)359-7700

1-800-TC OMEGA

[email protected]

B.

DMD-480-S2 SERIES DIP SWITCH SETTINGS

1.

SET THE DESIRED ADDRESS FOR EACH UNIT BY SETTING
SWITCHES 1-6.

BY SETTING THIS ADDRESS, THE UNIT IS GIVEN ITS OWN IDENTITY TO
WHICH THE HOST COMPUTER WILL IDENTIFY WITH.

• THE ADDRESS RANGE IS FROM 0 - 63 (DECIMAL) OR

111111 (BINARY).

(REFER TO EXAMPLES IN TABLE 3).

• SWITCH “ON” = 0; SWITCH “OFF” = 1

2.

SET THE DESIRED MODE OF OPERATION FOR THE 4570-232 USING
SWITCHES 7 & 8.
(REFER TO TABLE 2 FOR DEFINING MODES OF OPERATIONS)

MODE 3 IS USED FOR DIAGNOSTIC PURPOSES.

C.

SOFTWARE INSTALLATION

THE SUPPLIED OMEGA SOFTWARE, C4500.BAS, IS INTENDED FOR
USER MODIFICATION. PLEASE FEEL FREE TO MAKE ANY CUSTOM
MODIFICATIONS TO THE SOFTWARE AS NEEDED. IT IS RECOMMENDED
THAT THE USER MAKE A BACKUP COPY OF THE ORIGINAL OMEGA
SOFTWARE BEFORE MODIFYING.

1.

TO EXECUTE THE OMEGA C4500 SOFTWARE, QBASIC OR GWBASIC
MUST BE LOADED ON YOUR COMPUTER.

2.

TO BEGIN THE SOFTWARE SETUP, YOU MUST LOAD AND EXECUTE
THE SUPPLIED OMEGA PROGRAM, “C4500.BAS” WITHIN QBASIC OR
GWBASIC.

D.

SETUP MENU

THE FIRST MENU TO APPEAR IS THE “SETUP MENU”

IF YOU WANT TO SAVE ANY SETTINGS WHICH WILL BE ENTERED INTO THE
PROGRAM, YOU WILL WANT TO ENTER THOSE SETTINGS DIRECTLY INTO THE
SOFTWARE AND SAVE THE SOFTWARE WITH AN APPLICATION NAME
(XXXXX.BAS). AFTER YOU QUIT THE OPERATION MENU OR TURN OFF THE HOST
COMPUTER, ALL SETTINGS WILL RETURN TO THEIR DEFAULT VALUES UNLESS
SAVED.

TABLE 3: ADDRESS EXAMPLES

ADDRESS 63

BINARY = 101010

DECIMAL = 1 + 0 + 4 + 0 + 16 + 0 = 21

ADDRESS 21

BINARY = 100000

DECIMAL = 1 + 0 + 0 + 0 + 0 + 0 = 1

ADDRESS 1

BINARY = 111111

DECIMAL = 1 + 2 + 4 + 8 + 16 + 32 = 63

SW 7 SW 8 MODE

DESCRIPTION

ON

ON

0

OPERATE MODE: Operate Mode: Unit Outputs a reading

whenever it is addressed by the the host computer.

OFF

ON

1

TEST MODE: Unit outputs a reading every 0.33 seconds

continuously without being addressed

ON

OFF

2

UNDEFINED:

OFF

OFF

3

TEST MODE: Unit outputs a message " MODE 3: Version: 941124

Address: 01" continuously.

TABLE 2:

SWITCH

DECIMAL VALUE

1

1

2

2

3

4

4

8

5

16

6

32