CONNECTING THE UNIT

CAUTION: A 5-micron filter (TSD800-6), not included, must be installed with the unit to
ensure proper air filtration.















Figure 2.0









6

SETUP INSTRUCTIONS
Refer to Figure 1.0

6.1 Manual Dispense Cycle Setting:

1. Turn on the unit by pressing the Power button (1)
2. Press the Mode button (2) until “PURGE” appears on the Display.
3. Turn up the air pressure by rotating the Air pressure regulator knob (6) until

the desired pressure is indicated on the Air pressure gauge (5)

4. After filling the barrel or using pre-packaged adhesive, attach syringe to

receiver head assembly. Make certain that the syringe locks into place.

5. Connect the plug end of the receiver head assembly to one of the air

dispense outlet (7)

6. If vacuum “suck back” is needed, rotate the Vacuum regulator (8) counter

clockwise until the desired vacuum pressure is obtained

7. Press and hold the Foot switch to activate dispensed cycle. (The

Purge/Manual Mode is now activated)

6.2 Automatic Dispense Cycle Setting:

1. Push the Mode button (2) to select “TIMED” mode
2. Rotate the Time control knob (9) to set desired dispense time
3. Repeat step 3 to 6 in Section 6.1
4. Depress Foot switch to activate timed dispensed cycle


Items Description

1

To Air Source

2

Air Filter (Not included)

3 Power

Adapter

4 Foot

Switch

2

1

3

4

6

6.3 Cycle Counter

The cycle counter records the numbers of dispense cycle being activated. Up
to 65,535 cycles can be recorded. This number is shown at the lower right
hand corner of the LCD. Press the Counter Reset button (3) to clear the
counter.

7

TROUBLESHOOTING


PROBLEM POSSIBLE

CAUSE CORRECTION

LCD does not
light

No power input


Check power cord
connections

Turn on power

System will not
actuate

Foot switch not
plugged in or
improperly plugged
in

Defective foot
switch

Broken wire or loose
connection inside
unit



Defective solenoid

Defective PC board

Check foot switch
connection



Foot switch needs to be
repaired or replaced

Unplug power cord and
disconnect air supply.
Remove cover and check
for broken wires or loose
connections

Replace solenoid

Replace PC board

System will not
pressurize

Insufficient air
pressure

Air hoses not
plugged in

Regulator defective

Increase air supply
pressure

Check connection


Replace regulator

System will not
pull vacuum

Vacuum setting is
too low

Defective solenoid

Defective vacuum
venturi

Defective vacuum
needle valve

Increase vacuum setting

Replace solenoid valve

Replace venture

Replace needle valve

Inconsistent
dispensing

Air bubbles in
adhesive

Dispense time is too
low

Dispense needle
started to clog

Reduce vacuum setting

Increase dispensing time


Replace needle