Qmark MUH35C User Manual

Model no. muh35c, Installation, operation & maintenance instructions, Save these instructions

Advertising
background image

Read Carefully - These instructions contain vital information

for the proper installation, use and efficient operation of the

heater. Carefully read these instructions before installation,

operation, or cleaning of the heater. Failure to adhere to the

instructions could result in fire, electric shock, serious personal

injury, death or property damage. Save these instructions and

review frequently for continuing safe operation and instructing

future users.
IMPORTANT NOTE:
As received, heater is for hard wire installation and complies

with UL Standard 2021 and CSA Standard C22.2 No. 46-

M1988.
For Field Conversion to a Moveable Electric Heater, Model

PHCS1B Cord Kit must be installed. With Cord Kit installed,

complies with UL Standard 1278 and CSA Standard C22.2

No. 46-M1988. Refer to user instructions provided with Cord

Kit when using as a movable heater.
1. Use minimum 60 °C copper wire only.
2. Observe wall, floor, and ceiling clearance requirements

(page 2).

3. All wiring must conform to National and Local electrical

codes, and the heater must be grounded as a precaution

against possible electrical shock.

4. All electrical power must be disconnected at main service

box before installation, inspection, cleaning, or servicing of

this heater.

5. Check heater voltage and amperage on back of heater to

make sure it agrees with the electric service supplied.

6. Ground fault circuit protection is required if heater is used in

damp areas such as basements or garages. This heater is

not suitable for use in wet or very humid locations.

7. Do not use outdoors.
8. Never locate heater where it may fall into a bathtub or other

water container.

9. Do not insert or allow foreign objects to enter any ventilation

or exhaust opening as this may cause an electric shock, fire,

or damage the heater.

10. To prevent a possible fire, do not block air intakes or

exhaust in any manner. Do not use on soft surfaces, like a

bed, where openings may become blocked. Clean as often

as necessary to prevent dust from clogging the grille or ele-

ment fins. Keep all electrical cords, drapes, paper, plastics

and other combustibles away from heater.

11. Heater air flow must be directed parallel to or away from

adjacent walls.

12. A heater has hot and arcing or sparking parts inside. Do not

use it in areas where gasoline, paint, or flammable liquids

are used or stored.

13. If this heater or its power supply cable become damaged or

malfunction in any way, disconnect power at main service

panel, discontinue use, and have unit repaired by a rep-

utable repair service.

14. Do not operate heater without stand.
15. When heater is to be wall or ceiling mounted, the anchoring

provisions must be of sufficient strength to support the total

weight of the heater plus the weight of the mounting provi-

sions. Failure to properly secure the supporting members of

the building structure could allow the heater to fall.

SAVE THESE INSTRUCTIONS

!

Dear Owner,
Congratulations! Thank you for purchasing this new heater manufactured by Marley Engineered Products.

You have made a wise investment selecting the highest quality product in the heating industry.

Please carefully read the installation and maintenance instructions shown in this manual. You should enjoy

years of efficient heating comfort with this product from Marley Engineered Products... the industry’s leader in

design, manufacturing, quality and service.

... The Employees of

Marley Engineered Products

Installation, Operation & Maintenance Instructions

WARNING

MODEL NO. MUH35C

Unit Heater Fan-Forced

Built-in Thermostat

Advertising