Quantum Scalar 50 Tape Drive Installation Instructions
Document 81-81769-01 B01
September 2007

14

Completing the Native Fibre Channel Installation

6

To change a SCSI ID, enter the ID number in the field next to the device

and click

Apply

.

7

From the

Operations

page, click on the

Drives

tab.

The

Drives

page displays (see

figure 15

):

Figure 15 Drives Page

8

Enter the new tape drive number

9

Select

shutdown

and click

Apply

.

The tape drive powers down.

10

Enter the new tape drive number

11

Select

Power on

and click

Apply

.

The tape drive powers on. The tape drive installation is complete.

Completing the Native Fibre Channel Installation

0

After native Fibre Channel tape drives are installed, additional information

must be gathered to complete the installation and verify connectivity.

Competing the native Fibre Channel tape drive installation consists of the

following steps:

Note:

The firmware revision on the new tape drive(s) must match the

firmware revision on the currently installed tape drives (of the

same tape drive type). If the new tape drive has a different

revision, you must download the appropriate tape drive firmware

from Quantum and update the drive. All tape drives in the library

must contain the same firmware revision. You can view the tape

drive firmware revision on the OCP under

Drive Operations

.

Drive operations