Physical & environmental approvals, Table 20 - mechanical approvals, 0 physical & environmental approvals – Quatech 802.11B/G User Manual

Page 39

Advertising
background image

Airborne Enterprise Module Databook

Quatech, Inc.

100-8080-120

7/15/2010

39

12.0 Physical & Environmental Approvals

The device has passed the following primary physical and environmental tests. The test
methods referenced are defined in SAE J1455 Aug1994.

Table 19 - Mechanical Approvals

Test

Reference

Conditions

Temperature Range

(Operational)

Table 1B, Type 2b

-40°C to +85°C

Temperature Range (Non-
Operational)

-50°C to +125°C

Humidity

Sect 4.2.3

0-95%RH @ 38°C condensing

Fig 4a – 8 hours active humidity cycle

Altitude

Sect 4.8

Operational: 0-12,000ft (62 KPa absolute pressure)

Non-operational: 0-40,000ft (18.6 KPa absolute

pressure)

Vibration

Sect 4.9

Operational: 2.4 Grms, 10-1K Hz, 1hr per axis

Non-operational: 5.2 Grms, 10-1K Hz, 1hr per axis

Shock

Sect 4.10

Operational: 20Gs MAX, 11ms half-sine pulse

Product Drop

Sect 4.10.3.1

1m onto concrete, any face or corner, 1 drop

Packaging Drop

Sect 4.10.2.1

32 inches onto concrete on each face and corner.

Packaged in ‘for transit’ configuration.

Accelerated Life Test

MIL-STD-883

Method 1015

1000hrs @ 125°C, static bias

Test reports are available from Quatech Technical Support, please contact directly for the
latest documentation.