Use:

Contact Closure Feature

Contact Closure Feature

The contact closure feature is used to trigger gain changes

in the DSP. Any configuration that uses one or more

switched gain objects (see Signal Manager software Help

file ) can take advantage of this feature. The contact

closure will trigger all switched gain objects at once.

All switched gain objects in a DSP configu-

ration will be triggered by the one contact

closure. It is not possible to trigger

switched gain objects individually!

This feature requires the construction of a simple RS-232 cable (or through-adapter plug) that brings

out pins 5 (GND) and 9 (contact closure trigger). These pins may be connected to a simple toggle or

pushbutton switch that will be used to trigger a switched gain object in a DSP configuration. Refer to

Signal Manager software Help file for available contact closure features.

Wiring Diagram for Contact Closure