Acknowledgment, References – Quantum Instruments Sensor User Manual

Page 11

Advertising
background image

Sensors & Transducers Journal, Vol.76, Issue 2, February 2007, pp.935-936

of technology. The level of sophistication, awareness, cost, reliability, availability and marketing are
all factors involved in deciding, whether biosensors would become popular in near future.

Acknowledgment


Biosensor work in author’s lab is funded by Department of Biotechnology and Department of Science
& Technology, New Delhi.

References

[1]. M. Mascini, Affinity electrochemical biosensors for pollution Control. Pure. Appl. Chem. 73 (2001),

pp. 23–30.

[2]. Duane Lindner, The µchemLab TM project: micro total analysis system. R&D at Sandia National

Laboratories, Lab on a chip, 1 (2001), pp. 15-19.

[3]. F M Burkle, Measures of effectiveness in large-scale bioterrorism events. Prehosp. Disast. Med. 18 (2003),

pp. 258–262.

[4]. R. Eden-Firstenberg, and B J Schaertel, Biosensors in the food industry: present and future. J. of Food

Protection. 51(1988), pp. 811-820.

[5]. B. D. Malhotra, and A. Chaubey, Biosensors for clinical diagnostic Industry. Sensors Actuators B, 91

(2003), pp. 117-126.

[6]. Mart Chaplin, What are biosensors? (http://www.lsbu.ac.uk/biology/enztech/biosensors.html)
[7]. L. C. Clark, and C. Lyons, "Biosensors - A Practical Approach", Jnr. Ann. N. Y. Acad. Sci. 102 (1962),

pp. 29-45.

[8]. R. Blonder, S. Levi, G. Tao, I. Ben-Dov, and I. Willner, Development of Amperometric and

Microgravimetric Immunosensors and Reversible Immunosensors Using Antigen and Photoisomerizable
Antigen Monolayer Electrodes. J. Am. Chem. Soc.119 (1997), pp. 467-478.

[9]. R Blonder, I Ben-Dov, A Dagana, I Willner, and E Zisman, Photochemically-Activated Electrodes:

Application in Design of Reversible Immunosensors and Antibody Patterned Interfaces. Biosens.
Bioelectron. 12(1997), pp. 627-644.

[10]. T Gregory Drummmond, Electrochemical DNA sensors. Nature Biotechnol. 21(2003), pp. 1192-1199.
[11].Robert M Umek, Electronic detection of Nucleic acids. J. of Mol. Diagnostics.3(2001), pp. 74-84.
[12].KC Ho, CY Chen, HC Hsu, LC Chen, SC Shiesh and XZ Lin, Amperometric detection of morphine at a

prussian blue- modified indium tin oxide electrode. Biosens. Bioelectron. 20(2004), pp. 3-8.

[13].I Ben-Dov , I Willner, and E Zisman , Piezoelectric Immunosensors for Urine Specimens of Chlamydia

trachomatis Employing Quartz-Crystal-Microbalance Microgravimetric Analyses. Anal. Chem. 69(1997),
pp. 3506-3512.

[14].Masaharu Murata, Piezo Electric Sensor For Endocrine-Disrupting Chemicals Using Receptors-co- factor

Integration. Anal. Sciences. 19 (2003), pp. 1355-1357.

[15].B Xie, Mini/micro thermal biosensors and other related devices for biochemical/clinical monitoring.

TRAC, 19 (2000), pp. 340-349.

[16]. Mehrab Mehrvar, Fiber- Optic Biosensor-Trends and Advances. Anal. Sciences. 16 (2000), pp. 677-692.
[17]

.Brouwers, Annelies, Bernard, Dirk, Langlois, Michel,

Clinical and Analytical Performance of the

Accu-Chek Inform Point-of-Care Glucose Meter. Point of Care. 4 (2005), pp. 36-40.

[18].Pioneering the next generation of drug delivery and Biosensing

(http://boston.craigslist.org/nwb/lgl/278040060.html)

[19]. M Pizzi ,O D Martiis, V Grasso, Fabrication of Self Assembled Micro Reservoirs for Controlled Drug

Release. Biomedical Microdevices. 6 (2004), pp. 155-158.

[20]. Hanno L. Tan, Connie R. Bezzina, P. P. Jeroen, Smits, O. Arie, Verkerk and A. M. Arthur Wilde, A

calcium sensor in the sodium channel modulated cardiac excitability. Nature. 415 (2002), pp. 442-447.

[21]. Gary D Christian, Reagents for lithium electrodes and sensors for Blood Serum Analysis. Sensors. 2(2000),

pp. 432-435.

[22]. Vikas, Harish, and D. S. Ahlawat, Novel Fabrication of CA Membrane Bound Carbon Electrode for Bi-

enzymatic Determination of Lactate. Sensors & Transducers. 73 (2006), pp. 804-809.

943