Appendix, Specifications- powerlight 6.0 ii electrical data – QSC Audio 6.0 II User Manual

Page 25

Advertising
background image

25

APPENDIX-

DataPort Pinout

The DataPort connection is QSC-specific. Informa-
tion is subject to change.

SPECIFICATIONS- PowerLight 6.0 II Electrical Data

QSControl Control and Monitor Parameters

on/standby, channel gain, mute, polarity, input level, output level, heat sink

temperature, output load sense, clip detect, protect detect, operating Mode

sense (Stereo/Parallel/Bridge)

Cooling

four continuously variable speed fans, rear to front airflow

Amplifier Protection

short circuit, open circuit, thermal, ultrasonic, and RF protection

stable into reactive or mismatched loads

Load Protection

turn-on and turn-off muting, DC fault power supply shut down

Weight

53 lbs (net), 60 lbs (shipping)

Power Requirements

120 Volts AC, 50 to 60 Hertz, 30 Amp NEMA L5-30 receptacle

OR

240 Volts AC, 50 to 60 Hertz, 15 Amp service

Current Consumption

(in amperes, rms)

Current Consumption Notes:

Typical- 1/8 power, pink noise, represents typical program with occasional clipping

Full- 1/3 power, pink noise, represents severe program with heavy clipping

Maximum- continuous sine wave at 1% clipping

Note: Specifications are subject to change without notice.

Pin

Signal Description

1

Ch. 1 Minus (-) Input Signal

2

AC Standby Control

3

V- MON Ch. 1 and Subcode 1

4

I- MON Ch. 1 and Subcode 2

5

Clip/Protect Ch. 1

6

Hard Ground

7

Ch. 1 Plus (+) Input Signal

8

Ch. 2 Plus (+) Input Signal

9

+15V from Amplifier

10

Data Reference Ground

11

Ch. 2 Minus (-) Input Signal

12

Amplifier IDR (Model ID)

13

V- MON Ch. 2 and Subcode 3

14

I- MON Ch. 2 and Subcode 4

15

Clip/Protect Ch. 2

120 Volts

240 Volts