Hints for test centres

Before starting any test it is necessary to fill completely with salt the salt container and with rinse aid the rinse
aid dispenser.

IST10en

Test standard

EN 50242

Reference programme:

BIO WASH 50°

Load:

12 standard place settings

Rinse aid selector:

position 5

Detergent dosage :

25 g in the dispenser

5 g on the dispenser lid

UI49

US57

Arrangement
upper basket

Arrangement

lower basket

Arrangement

cutlery basket

DIMENSIONS

Width

60 cm

Height with worktop

85 cm

Height without worktop

82 cm

Max depth

61 cm

Max depth with open door

115.2 cm

ELECTRICAL CONNECTION

Voltage

230 V - 50 Hz

MOTOR RATING DURING WASH

200 W

POWER OF HEATING ELEMENT

2100 W

OVERALL POWER

2300 W

WATER SUPPLY PRESSURE

Minimum

50 kPa (0.5 bar)

Maximum

800 kPa (8 bar)

CAPACITY

12 place settings