4 • recording—advanced recording – Tascam CD-RW700 User Manual

Page 22

Advertising
background image

4 • Recording—Advanced recording

22

TASCAM CD-RW700

threshold for more than two seconds, and sound
has re-started

To enable or disable automatic track division:

1

With a recordable disc inserted, and with the
unit in record ready mode, press the

MENU

key

(

9

or

7

) repeatedly until

A_TRACK>XX

is shown, where

XX

may be

ON

or

OFF

.

2

Turn the

MULTI JOG

control

B

or use the

SKIP

keys

I

to change the value to

ON

or

OFF

.

The

A-TRACK

indicator at the top right of the

display lights when the auto track function is
enabled.

Automatic track division can be turned on or off
while recording is taking place.

NOTE

When recording certain types of material (e.g. certain
types of classical music or spoken word) through the
analog connections, since the track divisions are
determined by relative silence, it is possible that spu-
rious track divisions will be inserted. Under these
conditions, it may be better to use manual track divi-
sion (4.2.3, “Manual track division”).

However, if recording through a digital connection, the track
number will be incremented only when a track division sig-
nal is received, followed by a rise in volume.

A fall and subsequent rise in volume alone when recording
digitally from CD, MD or DAT is not sufficient to trigger an

automatic track increment.

You may find it helpful to use the track restriction
facility (see 4.2.4, “Restricting the number of
tracks”) together with the automatic track division.

For instance, if you have recorded two albums on one
DAT tape, and you wish to make two separate CDs
from this tape, you can use the

MULTI JOG

control to

set the number of tracks to the number of tracks com-
prising the first album.

When the final track of the first album has been
recorded, the unit automatically performs the PMA
writing procedure and enters stop mode.

4.3.4

Digital direct

As mentioned earlier, the digital direct mode
bypasses some of the input circuitry of the CD-
RW700 (the frequency convertor and the digital level
control) to write directly to the disc.

To enable or disable digital direct recording:

1

Ensure that the input source is set to

DIGITAL

(either

COAXIAL

or

OPTICAL

).

2

Press the

DIGITAL DIRECT

key

5

(main unit

only). The display shows

D_Direct XX

where

XX

is

ON

or

OFF

.

time

level

S_LVL

At least 2

seconds

Track
increment

time

level

S_LVL

Track incremented

Track start signal
received

time

level

S_LVL

Long "pause"
in signal, but
track is not
incremented

Digital recording from CD, MD and

Advertising