III. c - INSTALLING CASTERS (cont’d):
or compartment, for proper support. See drawing on
page 6 for correct placement.

III. d - INSTALLING LEGS:
Optional legs are installed in the same manner as cast-
ers (see figure 1). When the unit is set in its
finalposition it is important for proper operation that
the unit be leveled. The legs are adjustable for this
purpose.

Please note that Traulsen units are not designed to be
moved while on legs. If the unit requires moving, a
pallet jack or forklift should be used to prevent dam-
age.

III. e - CORD & PLUG:
All self-contained models are supplied with a cord &
plug attached. It is shipped coiled at the bottom of the
cabinet, secured by a nylon strip. For your safety and
protection, all units supplied with a cord and plug in-
clude a special three-prong grounding plug on the ser-
vice cord. Select only a certified electrical outlet with
grounding plug for power source. NOTE: Do not un-
der any circumstances, cut or remove the round
grounding prong from the plug, or use an extension
cord.

III. f - POWER SUPPLY:
It is recommended that the supply voltage be checked
prior to connection to be certain that proper voltage
for the cabinet wiring is available (refer to the serial
tag to determine correct unit voltage). Make connec-
tions in accordance with local electrical codes. Use
qualified electricians.

Use of a separate, dedicated circuit is required. Size
wiring to handle indicated load and provide necessary
overcurrent protector in circuit.

III. g - CLEARANCE:
It is important for the proper operation and longevity
of your Traulsen unit that it have adequate provisions
for air supply to the compressor. Do not store materi-
als within 31” of the condensing unit louvers. Inad-
equate air flow circulation and heating will result if the
air flow is obstructed.

III. h - WIRING DIAGRAM:
Refer to the wiring diagram for any service work per-
formed on the unit. Should you require one, please
contact Traulsen Service at (800) 825-8220, and pro-
vide the model and serial number of the unit involved.

-2-

II. RECEIPT INSPECTION

All Traulsen products are factory tested for perfor-
mance and are free from defects when shipped. The
utmost care has been taken in crating this product to
protect against damage in transit. All legs or casters
are boxed inside to prevent damage.

You should carefully inspect your Traulsen unit for
damage during delivery. If damage is detected, you
should save all the crating materials and make note
on the carrier’s Bill Of Lading describing this. A freight
claim should be filed immediately. If damage is sub-
sequently noted during or immediately after installa-
tion, contact the respective carrier and file a freight
claim. Under no condition may a damaged unit be re-
turned to Traulsen & Co. without first obtaining writ-
ten permission (return authorization).

III. a - LOCATION:
Select a proper location for your Traulsen unit, away
from extreme heat or cold. Allow enough clearance
between the unit and the side wall so that the door (s)
may open a minimum of 90

°

.

III. b - PACKAGING:
All Traulsen VPS units are shipped from the factory
on a sturdy wooden pallet and packaged in a durable
crate with staples. These should first be removed to
avoid scratching the unit when lifting off the crate.
Avoid laying the unit on its front, side or back for re-
moval of the pallet.

NOTE: Traulsen does not recommend laying the unit
down on its front, side or back. However, if you must
please be certain to allow the unit to remain in an up-
right position afterwards for 24 hours before plugging
it in so that the compressor oils and refrigerant may
settle.

III. c - INSTALLING CASTERS:
Six (6) 8” high casters are supplied standard for all
VPS units. These are shipped from the factory packed
inside a cardboard box, contained within the unit.

WARNING: THE CABINET MUST BE BLOCKED AND
STABLE BEFORE INSTALLING LEGS OR CASTERS.

To install the legs or casters, first raise and block the
unit a minimum of 9” from the floor. The casters slide
into the two leg channels on the front and back of the
cabinet. These are fully adjustable along the unit’s
entire length to allow for avoiding floor obstructions,
such as drains and outlet boxes. Be certain that all
casters are tightly secured; to do this, tighten the two
bolts located at the base of each caster assembly.

NOTE: Casters or legs must be installed towards the
four corners of the unit, as well under the compress-

III. INSTALLATION