1introduction, Introduction, 1 description – Transition Networks POINTSYSTEM CPSMC0810-100 User Manual

Page 4: Auxiliary power inlet grounding lugs

Advertising
background image

4

CPSMC08xx-100 PointSystem™ Chassis

introduction

1

Introduction

1.1

Description

The Transition Networks PointSystem™ CPSMC08xx-100 is a 19-inch, rack-
mountable chassis for selected Transition Networks media converter slide-in-
modules. The chassis allows the network administrator to connect various copper
and fiber-optic network media over protocols that include Ethernet, Fast Ethernet,
DS3/E3, and OC-12. The chassis provides installation space for up to eight (8)
single-slot or four (4) dual-slot media converter slide-in-modules in the front of the
unit.

The CPSMC0800-100 comes equipped with an AC power supply. The CPSMC0810-
100 comes equipped with a DC power supply. An optional, auxiliary AC or DC
power supply with instant fail over operation is also available for either model. The
primary power supply is accessed through the power inlet on the front panel, while
auxiliary power is accessed through the auxiliary power inlet, located on the back
panel.

The CPSMC08xx-100 also comes equipped with a pair of grounding lugs for
providing proper grounding of the chassis.

Multiple fans help remove heat from the chassis.

With installed PointSystem™ management module(s) (P/N CPSMM-120, -200, or
-210), the CPSMC08xx-100 can be managed and monitored via:

An SNMP application such as Transition Networks FocalPoint™ management
software installed at a remote Network Management Station (NMS).

A remote Web browser.

A command-line interface (CLI) at an attached terminal.

A command-line-interface (CLI) at a remote Telnet connection.

The management modules also make it possible to control up to eight (8) cascaded
chassis, fully-populated with installed media converter slide-in-modules.

24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600

10BASE-T

INPORT

MCCM10

MGMT

MASTER

OUTPORT

12C

12C-1

TERM

INIT

RX

TX

LNK

PWR

RESET

DB-9

CFETF1

10

SPD

PWR

FRX

CRX

FLNK

CLNK

10/100TX

RX

TX

10/100SX

LKS

PWR

LKM

Multimode

Singlemode

TX

RX

TX

RX

CFETF1

10

SPD

PWR

FRX

CRX

FLNK

CLNK

10/100TX

RX

TX

10/100SX

LKS

PWR

LKM

Multimode

Singlemode

TX

RX

TX

RX

CPSMC-0800
8-Slot Chassis

Mpls, MN 55344

Mpls, MN 55344

Input Power:

Input Power:
110-240 VAC

110-240 VAC
1.6A max. (60W max)

1.6A max. (60W max)
50/60 Hz

50/60 Hz

Management Module Installed Slide-In-Module

Open Slot

Power Inlet

Mpls, MN 55344

Input Power:
110-240 VAC
1.6A max. (60W max)
50/60 Hz

Auxiliary Power Inlet

Grounding Lugs

Advertising
This manual is related to the following products: