VOLTAGE REGULATION

Voltage regulation
description

Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 81 to 143

Overvoltage correction

Input voltages between 128 and 143V are reduced by 9%

Undervoltage correction

Input voltages between 97 and 107V are boosted by 10%

Severe undervoltage
correction

Input voltages between 81 and 96V are boosted by 21%

LEDS ALARMS & SWITCHES

LED Indicators

5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status

Alarms

Audible alarm indicates power-failure and low-battery conditions

Alarm cancel operation

Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate
low-battery status

Switches

2 Switches control off/on power status and alarm-cancel/self-test operation

SURGE / NOISE SUPPRESSION

UPS AC suppression joule
rating

510

UPS AC suppression
response time

Instantaneous

EMI / RFI AC noise
suppression

Yes

ISOLATION

Output isolation transformer

Professional grade load isolation transformer

Surge voltage withstand
capability

ANSI/IEEE C62.41 Categories A & B 6KV/200/500 amp 100Khz Ringwave and category B BiWave

Surge voltage attenuation

N-G 2000:1, L-G 240:1, L-N 100:1

Insertion loss

65 db N-G from 10Khz to 100Khz, 45 to 60 db L-G from 10Khz to 100Khz, 18 to 54 db L-N from 50Khz to 500
Khz

PHYSICAL

Installation form factors
supported with included
accessories

Tower

Installation form factors
supported with optional
accessories

Wallmount (UPSWM - tower mounting kit)

Primary form factor

Tower

UPS / Power Module
dimensions in primary form
factor (height x width x
depth / inches)

12.8 x 7.5 x 9.2

UPS / Power Module
dimensions in primary form
factor (height x width x
depth / cm)

32.4 x 19 x 23.5

UPS / Power Module weight
(lbs)

36.4

UPS / Power Module weight
(kg)

16.5