For use with Transition Networks Model SIBTF10xx-1xx-Mx or equivalent.

Standards:

IEEE 802.3™ 2000, IEEE 802.3x™

Data Rate:

10 Mb/s, 100 Mb/s (copper), 100 Mb/s (fiber)

Dimensions:

Models 130- & 140-Mx
(W x H x D) 4.125" x 6" x 5" (104.77 x 152.4 x 127 mm)

Dimensions:

Model 110-Mx
(W x H x D) 3.375" x 6" x 5" (85.73x 152.4 x 127 mm)

Weight:

3.2 lb. (1.5 kg) approximately

Input Voltage:

48170VDC +/-15%
90125VAC +/-15%, 50/60 Hz

Power:

15 W (maximum)
Aux input standby power, 200 mW typically

Fuse:

2.5 A/250 VDC

Alarm Relay:

Three-position screw terminal block for the dry contact relay
0.5 A @ 125 VAC / 2.0 A @ 30 VDC (maximum)
switching capacity: 60 W (maximum)

Packet Size:

Memory: 64K Bytes
Unicast MAC addresses: 1000
Maximum packet size: 1536 Bytes

MTBF*:

51,115 MIL-HDBK-217F Hours
153,038 Bellcore Hours

Environment
Operating Temp:

-40 to 75°C (-40 to 167°F)

Storage Temp:

-40 to 85°C (-40 to 185°F)

Humidity:

5 to 95%, non-condensing

Altitude:

3000 m (10,000 ft.)

Warranty:

Lifetime

The industrial switch is designed for installation in restricted access locations.
Installing the industrial switch into other equipment or facility control rooms must
comply with the fire-enclosure requirements of IEC60950/EN60950/UL60950, along
with other local, national fire and safety codes.

IMPORTANT: Copper based media ports: e.g., Twisted Pair (TP) Ethernet, USB,
RS232, RS422, RS485, DS1, DS3, Video Coax, etc. are intended for connecting to
intra-building (inside plant) link segments, not subject to lightening transients or
power faults. Copper based media ports: e.g., Twisted Pair (TP) Ethernet, USB,
RS232, RS422, RS485, DS1, DS3, Video Coax, etc. are NOT for connecting to inter-
building (outside plant) link segments subject to lightening transients or power faults.

*MTBF is estimated using the predictability method. This method is based on MIL-
217F at 25°C ambient temperature, typical enclosure heat rise of 10°C, and nominal
operating conditions and parameters. Installation and configuration specific MTBF
estimates are available upon request. Contact Technical Support.

[email protected] -- Click the “Transition Now” link for a live Web chat.

23

Technical Specification -- continued

220–240VAC, 50/60Hz installation

CAUTION: If the main power source is 220-240VAC @50/60Hz, use a 2:1, 50VA or
greater step-down transformer between the main power source and the industrial
switch. Failure to observe this caution could result in a damaged switch.

Standard

Description

Compliance Level

Remarks

EN55022/FCC Part15

ITE Emissions

Class A

Conducted and radiated

EN55024/EN61000-6-2:

ITE Emissions

IEC61000-4-2

Level 2

ESD contact discharge

IEC61000-4-3

Level 4

Radiated fields

IEC61000-4-4

Level 3

Fast transients - power port
2 meter cable AC
1 meter cable DC

Level 2

Fast transient – Ethernet port
3 meter cable length

IEC6100-4-5

Level 3 CM
Level 2 DM
Level 1 DC

Surge – power port
2 meter cable AC
1 meter cable DC

Level 2

Surge – relay port
1 meter cable length

Level 2

Surge – Ethernet port
3 meter cable length

IEC61000-4-5

EN61000-6-2 Level 3
EN55024 Level 2

Conducted – power port
2 meter cable AC,
1 meter cable DC

EN61000-6-2 Level 3
EN55024 Level 2

Conducted – relay port
1 meter cable length

EN61000-6-2 Level 3
EN55024 Level 2

Conducted – PE Studs
2 meter cable length

EN61000-6-2 Level 3
EN55024 Level 2

Conducted – Ethernet port
10 meter cable length

IEC61000-4-8

Level 1

Power freq. mag. field

IEC61000-4-11

N/A

VoltageDIPs and variations

IEEE1613, Power Substation Testing

IEEE1613, Clause 6.2

Not rated

Dielectric power freq.

IEEE1613, Clause 6.3

Compliant

Impulse voltage all ports

IEEE1613, Clause 7.3.1

Class 2 transverse and
common Mode

Surge oscillatory waveform
–power AC

Class 2 transverse and
common Mode

Surge oscillatory waveform
–power DC

Class 2 common mode

Surge oscillatory waveform
–relay port

Class 2 common mode

Surge oscillatory waveform
–Ethernet 10 Mbps

Class 1 common mode

Surge oscillatory waveform
– Ethernet 100 Mbps

EMC Type Tests (all test were performed using unshielded cables)

Advertising
This manual is related to the following products: