Troubleshooting guide – True Manufacturing Company Swing Glass Door Merchandiser Refrigerator GDM-26 User Manual

Page 9

Advertising
background image

2001 East Terra Lane • O'Fallon, MO. 63366 • ph. 636.240.2400 • toll free 800. 325.6152 • [email protected]

TROUBLESHOOTING GUIDE

(Please note this does not cover any and all situations)

Complaint

Possible Cause

Repair

Cabinet not cold enough

1. No product in cabinet.

1. Load cabinet Elstat is

equipped with a anti-short

cycle that can make the unit

run warm with no product.

2. Unit in a unpredictable

location. Elstat control may be

going in standby mode.

2. Move cabinet or put into

Perishable mode.

3. Unit was in a previous

location.

3. Perform half reset.

Warm Product

1. Unit in a unpredictable

location. Elstat control may be

going into standby mode.

1. Move cabinet or put into

Perishable mode.

2. Compressor not running.

2. Check for out put voltage

at controller. If good follow

compressor diagnosis.

3. Compressor running.

3. Follow refrigeration trouble

shooting guides.

4. Unit in standby mode.

Unit displaying a
temperature instead of
“use.”

1. Unit recently worked

on. Parameters have been

changed.

1. Reset the DIS parameter to

“0”.

GDM SERIES COOLER EQUIPPED WITH EMS (ELSTAT) CONTROL

TROUBLESHOOTING GUIDE

9

Advertising