Features and benefits – Trane RTHD User Manual

Page 4

Advertising
background image

RLC-PRC020-EN

4

Features and
Benefits

Applications in this catalog specifically
excluded from the ARI certification
program are:
• Low temperature applications, including

ice storage

• Glycol
• 50Hz units below 200 nominal tons

Application Versatility and High
Performance
• Screw compressor technology and the

electronic expansion valve provide
reliable performance in an expanded
range of operating temperatures.

• Tight water temperature control extends

to operation of multiple chillers in
parallel or series configurations, offering
further system design flexibility for
maximum efficiency.

• Advanced design enables chilled water

temperature control to +/- 0.5°F (.28°C)
for flow changes up to 10 percent per
minute, plus handling of flow changes up
to 30 percent per minute for comfort
cooling.

• Two-minute stop-to-start and five-minute

start-to-start anti-recycle timer allows
tight chilled water temperature control
in constant or transient low-load
applications.

• LonMark communications capability

provides excellent, trouble-free
interoperability.

• Generic Building Automation System

points are available for easy access to
operational information.

• Extensive information on professional

design selection and layout is available
in a simple, highly readable electronic
format.

• Standard model RTHD configurations

are in stock and available for immediate
delivery, and Trane offers the fastest
ship cycles in the industry for built-to-
order units.

Industrial / Low Temperature Process

Cooling – Excellent operating
temperature range and precise control
capabilities enable tight control with
single chiller or series configuration.

Ice/Thermal Storage – Specifiers and

operators benefit from dual setpoint
control and industry-leading
temperature, efficiency, and control
capabilities, plus outstanding support
through partnership with Calmac, a
strong Trane partner providing proven
installation examples, templates, and
references that minimize design time
and energy costs.

Heat Recovery – Maximum condenser

temperature exceeds those of previous
technologies, providing hot water and
tight control that minimizes operating
costs for the chilled water plant and
boiler/hot water heater, and consistent
dehumidification.

Simple, Economical Installation
• Compact size makes the model RTHD

well suited for the retrofit and
replacement market.

• All units fit through standard double-

width doors.

• Bolt-together construction makes for

fast, easy unit disassembly.

• Small RTHD footprint saves valuable

equipment room space and alleviates
access concerns for most retrofit jobs.

• Lightweight design simplifies rigging

requirements, further reducing
installation time requirements and
costs.

• Full factory refrigerant or nitrogen and

oil charges reduce required field labor,
materials, and installation cost.

• Only evaporator and condenser water

piping is required; no starter water
cooling (with its associated safety
concerns) or field piping is necessary.

• Oil cooler and purge system

connections have been eliminated.

• Simple power connection simplifies

overall installation.

• Standard unit-mounted starter for

Wye-Delta and Solid State eliminates
additional jobsite installation
considerations and labor requirements.

• Trane has conducted extensive factory

testing, and also offers options for in-
person and/or documented system
performance verification.

• CH530 controls easily interface with

Tracer Summit

building automation

systems through single twisted-pair
wire.

Pueblo

Business Unit

Advertising