Technical specification, Troubleshooting, Continued – Transition Networks SISTF10XX-160-LR(T) User Manual

Page 9

Advertising
background image

16

SISTF10xx-140-LR(T) / -160-LR(T) / -170-LR(T)

24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600

Test

Description

Test Levels

IEC 60068-2-6

Vibration

10 - 500 - 10 Hz, 0.5 oct./min, 4g, X, Y, Z (3 axes)

IEC 60068-2-27

Shock

50 g, 11 ms, +/-X, +/-Y, +/- Z (6 direction)

IEC 60068-2-32

Free fall

75 cm, 1 corner, 3 edges, 6 faces (total 10 drops)

Environmental Type Tests

Test

Description

Test Levels

Severity

IEC61000-4-2 ESD

Air discharge

+/- 8 KV

3

Contact discharge

+/- 6 KV

3

ESD contact discharge

+/- 6 KV

3

IEC61000-4-3 Radiated RFI

Housing

10V/m, 80 MHz - 1 GHz
AM 1 KHz, 80% mod
10 V/m, 0.9 - 1.8 GHz
FM 200 Hz 50% square

3

IEC61000-4-4 Burst

(Fast Transient)

Power supply lines

+/- 2 KV

3

Communication lines

+/- 1 KV

3

Relay

+/- 1 KV

3

IEC61000-4-5 Surge

Power supply lines

+/- 2 KV, 12

Ω, CM

+/- 1 KV, 2

Ω, DM

3

Relay

+/- 2 KV, 12

Ω, CM

+/- 1 KV, 2

Ω, DM

3

IEC61000-4-6 Induced

(Conducted RFI)

Power supply lines

10 Vrms, 150-80 MHz
AM 1 KHz, 80% mod

3

Communication lines

10 Vrms, 150-80 MHz
AM 1 KHz, 80% mod

3

Relay

10 Vrms, 150-80 MHz
AM 1 KHz, 80% mod

3

EMS Type Tests

Technical Specification

-- Continued

This device has been evaluated as EEx nC IIC T4 equipment under DEMKO
Certificate No. 03 ATEX 0324537U. Each module is suitable for use in Zone 2
Explosive Atmospheres. The device must be installed in a minimum IP 54
enclosure as defined in IEC 60529 and EN 60529.

This device is a building-in type. The installation into a certain end equipment
shall comply with fire enclosure request of IEC 60950/EN60950 or similar
sentence.

[email protected] -- Click the “Transition Now” link for a live Web chat.

17

Troubleshooting

If the device fails, isolate and correct the fault by determining the answers to the
following questions and then taking the indicated action:

1.

Is the PWR1 LED illuminated?
NO

Ensure the power source is the proper voltage (12 - 48 VDC).

Ensure the (+) and (-) wires from the power source are inserted
properly in the terminal block contacts labeled “PWR1”.

Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.

YES

Proceed to step 2.

2.

Is the PWR2 LED illuminated?
NO

Ensure the power source is the proper voltage (12 - 48 VDC).

Ensure the (+) and (-) wires from the power source are inserted
properly in the terminal block contacts labeled “PWR2”.

Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.

YES

Proceed to step 3.

3.

Is the FAULT LED illuminated?
YES

If one or more port alarm switches (1 - 5) is ON

,

the device lost the

corresponding fiber or copper link, or the primary power or backup
power.

Ensure the problem copper or fiber link is properly connected.

Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.

NO

Proceed to step 4.

4.

Is a 100M LED (near a fiber link) illuminated?
NO

Check the corresponding fiber cables for proper connection.

Verify that the TX and RX cables on the device are connected to the
RX and TX ports, respectively, on the other device.

Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.

YES

Proceed to step 5.