Ordering information, Absolute maximum ratings, Recommended operating conditions – Texas Instruments TPS54810 User Manual

Page 2: Dissipation ratings

Advertising
background image

TPS54810

SLVS420B − MARCH 2002 − R EVISED FEBRUARY 2005

www.ti.com

2

These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam during
storage or handling to prevent electrostatic damage to the MOS gates.

ORDERING INFORMATION

T

A

OUTPUT VOLTAGE

PACKAGE

PART NUMBER

−40°C to 85°C

0.9 V to 3.3 V

PLASTIC HTSSOP (PWP)

(1)

TPS54810PWP

(1)

The PWP package is also available taped and reeled. Add an R suffix to the device type (i.e., TPS54810PWPR). See the application section
of the data sheet for PowerPAD™ drawing and layout information.

(2)

For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the TI website
at www.ti.com.

ABSOLUTE MAXIMUM RATINGS

over operating free-air temperature range unless otherwise noted

(1)

TPS54810

UNIT

VIN, SS/ENA, SYNC

−0.3 to 7

I

t lta

a

V

RT

−0.3 to 6

V

Input voltage range, V

I

VSENSE

−0.3 to 4

V

BOOT

−0.3 to 17

O t t lta

a

V

VBIAS, COMP, PWRGD

−0.3 to 7

V

Output voltage range, V

O

PH

−0.6 to 10

V

S

t I

PH

Internally Limited

Source current, I

O

COMP, VBIAS

6

mA

PH

12

A

Sink current, I

S

COMP

6

A

Sink current, I

S

SS/ENA, PWRGD

10

mA

Voltage differential

AGND to PGND

±0.3

V

Operating virtual junction temperature range, T

J

−40 to 125

°C

Storage temperature, T

stg

−65 to 150

°C

Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds

300

°C

(1)

Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.

RECOMMENDED OPERATING CONDITIONS

MIN NOM MAX UNIT

Input voltage range, V

I

4

6

V

Operating junction temperature, T

J

−40

125

°C

DISSIPATION RATINGS

(1) (2)

PACKAGE

THERMAL IMPEDANCE

JUNCTION-TO-AMBIENT

T

A

25°C

POWER RATING

T

A

= 70°C

POWER RATING

T

A

= 85°C

POWER RATING

28-Pin PWP with solder

18.2 °C/W

5.49 W

(2)

3.02 W

2.20 W

28-Pin PWP without solder

40.5 °C/W

2.48 W

1.36 W

0.99 W

(1)

For more information on the PWP package, refer to TI technical brief, literature number SLMA002.

(2)

Test Board Conditions:
1. 3” x 3”, 4 layers, thickness: 0.062”
2. 1.5 oz. copper traces located on the top of the PCB
3. 1.5 oz. copper ground plane on the bottom of the PCB
4. 0.5 oz. copper ground planes on the 2 internal layers
5. 12 thermal vias (see “Recommended Land Pattern” in applications section of this data sheet)

(3)

Maximum power dissipation may be limited by over current protection.

Advertising