ARCHITECT'S SPECIFICATIONS

The cassette player/recorder shall utilize a reversible

transport mechanism. Separate record and reproduce

heads shall be used allowing monitoring off tape.
Inputs and outputs shall be provided on unbalanced RCA

connectors on the rear panel. The option of balanced

XLR connectors shall be provided by the optional LA-112

balancing kit. An additional pair of 1/4" inputs shall be

located on the front panel. Levels shall be displayed on

large VU meters with peak LEDs for accurate display of

levels. The input level shall be controlled by separate

left and right controls on the front panel. Stereo output

level shall also be provided on the front panel for

convenience. Headphone output with level control shall

be provided on the front panel.
Monitor selection switch shall be provided on the front

panel for selection between input monitor mode and

automatic monitor mode. Dolby™ B and C noise reduction

shall be implemented and switched from the front panel.

An MPX filter shall be switchable from the front panel.
A pitch control will provide approximately ±12% range

of pitch control, with a dedicated on/off control.

The cassette deck shall have dedicated buttons to access

the RTZ function (Return to Zero) and two locate points.

An additional separate button shall trigger the repeat

function which will loop between locate 1 and locate 2.
A digital counter shall be used to display precise tape

location.
For extended cascade play or recording functions, the

cassette deck shall offer sequential triggers through the

parallel control allowing hands free continuous operation.
A parallel control shall be provided which can be used for

remote control and tallies, and it shall be compatible with

the TASCAM RC-112R remote control.
The cassette deck shall mount in a standard 19" rack mount

form, taking three rack spaces. The cassette mechanism

shall have dimensions of 19" x 5 1/4" x 14" (W x H x D).

Metric measurements : 482 x 132 x 356mm (W x H x D).

The unit shall be a TASCAM 112RmkII cassette deck.

NOTE: This text is available in a standard text file on TASCAM's
Sound Contractor CD-ROM. Contact TASCAM for details.

OPTIONAL REMOTE (RC-112R)

PARALLEL I/O

Pin

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

Signal

PLAY In

FFWD In

REW In

PAUSE In

STOP In

REC In

CASCADE START In

NOT USED

TAPE DIRECTION Tally

END OF TAPE Tally

FF Tally

REW Tally

PAUSE Tally

STOP Tally

REC Tally

NOT USED

REVERSE PLAY In

REVERSE PLAY Tally

REEL PULSE

NOT USED

RTZ In

FADER START In

NOT USED

GROUND

+5V (Max 50mA)

Control I/O Legend

16

18

20

15

17

19

21

24

22

14

23

25

1

3

5

7

2

4

6

8

9

11

13

10

12

Parallel Control Notes:

All command controls are labeled as "in" on
the chart at left. The commands are active
when brought to ground for more than 50
milliseconds or longer.

FADER START pin (22) operates as a latched
function. Playback begins when the pin is
brought to ground for more than 50 msec,
and stops when the ground is released for
more than 50 msec.

Tally outputs indicates the corresponding
transport function when the pin is brought
to ground.