5test setup – Texas Instruments TPS40090EVM-002 User Manual

Page 14

Advertising
background image

SLUU195 − June 2004

14

TPS40090 Multi-Phase Buck Converter and TPS2834 Drivers Steps-Down from 12-V to 1.5-V at 100 A

5

Test Setup

The HPA072 has the following input/output connections: 12-V input J1 (VIN) and J2 (GND),
1.5-V output J9 (VOUT) and J10 (GND). A diagram showing the connection points is shown in
Figure 5. A power supply capable of supplying 18 A should be connected to VIN and GND
through a pair of 10 AWG wires. The 1.5-V load should be connected respectively to J9 and J10
through pairs of 0 AWG wires. Wire lengths should be minimized to reduce losses in the wires.
A 5-inch fan with 200-cfm air flow is recommended to operate this board at full load.

TPS40090EVM−002

Board

J1

J2

J9

J10

Oscilloscope

CH1

J8

Electronic

Load

Fluke 45

12 V/ 20 A

Power

Supply

UDG−04063

VOUT DC

Figure 7. Connections for the Test

Advertising