Ethernet cable specifications – Transition Networks FD-CD-01(SM) User Manual

Page 2

Advertising
background image

MDI switch setting

MDI-X switch setting

100 meters

100 meters

2 kilometers - multimode
20 kilometers - singlemode

Straight Through/Crossover Cable Requirements and Pin Specifications

The two active pairs in a CDDI
network are pins 1 & 2 and
pins 7 & 8. Use only dedicated
wire pairs (such as blue/white
& white/blue, orange/white &
white/orange) for the active
pins.

1

2

7

8

Twisted
Pair #1

Twisted
Pair #2

Straight Through Cable

1

2

7

8

Straight-through/crossover CDDI requirements are satisfied using
the MDI/MDI-X switch with straight-through cable.

CDDI cable connections between a
concentrator and the media converter require
the MDI/MDI-X switch to be set to MDI.

CDDI cable connections between the media
converter and a NIC require the switch to be
set to MDI-X

MDI

MDI-X

12V DC Input

FD-CD-01

CDDI

FDDI

FDDI to CDDI

MDI-X

position

MDI

position

Using small flatblade screwdriver
or similar tool and referring to
label at front of media converter,
set MDI/MDI-X switch position for
site installation.

CDDI Cable

1. Is the power LED on the media converter illuminated?

NO

•

Is the power adapter the proper type of voltage and cycle frequency for your AC outlet?
NOTE: Refer to the “Power Supply Requirements” on the back page.

•

Is the power adapter properly installed in the media converter and in the outlet?

•

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

YES

•

Proceed to step 2.

2. Is the CDDI Link LED illuminated?

NO

•

Check UTP cables for proper connection and pin assignment. (See above.)

•

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

YES

•

Proceed to step 3.

3. Is the fiber Link LED illuminated?

NO

•

Check fiber cables for proper connection.

•

Verify that TX and RX cables on media converter are connected to RX and TX ports,
respectively, on the other FDDI device.

•

Refer to Tech Tips available at: http://www.transition.com

•

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

YES

•

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

Troubleshooting the Media Converter

Installation Notes

The physical characteristics of the media cable must meet or exceed ANSI
X3T12 FDDI specifications.

ETHERNET CABLE SPECIFICATIONS

FDDI CABLE SPECIFICATIONS

SINGLEMODE
Fiber-optic Cable Recommended:

9 µm singlemode fiber

Fiber-optic Transmitter Power:

min: -15.0

dBm

max: -8.0

dBm

Fiber-optic Receiver Sensitivity:

min: -32.5

dBm

max: -8.0

dBm

Wavelength:

1300nM

Bit error rate:

≤

10

-9

Maximum Cable Distance:

20 kilometers

MULTIMODE
Fiber-optic Cable Recommended:

62.5 / 125 µm multimode fiber

Optional:

100 / 140 µm multimode fiber

85 / 125 µm multimode fiber
50 / 125 µm multimode fiber

Fiber-optic Transmitter Power:

min: -19.0

dBm

max: -14.0

dBm

Fiber-optic Receiver Sensitivity:

min: -32.5

dBm

max: -14.0

dBm

Wavelength:

1300nM

Bit error rate:

≤

10

-9

Maximum Cable Distance:

2 kilometers

CDDI CABLE SPECIFICATIONS
Category 5 wire or better is required. Either shielded twisted pair
(STP) or unshielded twisted pair (UTP) can be used. DO NOT USE
FLAT OR SILVER SATIN WIRE.

CATEGORY 5:

Gauge

24 to 22 AWG

Attenuation

20 dB/1000’ @ 10 MHz

Impedance 100

Ω

±10% @ 10 MHz

Maximum Cable Distance:

100 meters (330 feet)

•

KEEP TWISTED PAIR RUNS AS SHORT AS POSSIBLE.

•

Be certain that the CDDI MDI/MDI-X switch is set correctly for site installation.

•

Connect the power supply cable to the media converter BEFORE connecting to the outlet.

•

Install unit with PSU provided. (Output 12 VDC regulated, 350 mA).

•

Install no more than two (2) media converters in series.

FD-CD-01, FD-CD-01(SM)