Grill, Main oven, General – Tricity Bendix CC500/1 User Manual

Page 27: Gas category countries of destination

Advertising
background image

27

Grill

Natural Gas

L.P. Gas

Heat Input

3.0kW (10236 Btu/h)

2.75kW (197.5g/h)

Injector marking

120

080

Main Oven

Heat input

2.4kW (8189 Btu/h)

2.4kW (172.4g/h)

Injector marking

108

078

Thermostat bypass marking

069

078

General

Ignition

(H.T. Spark)

Spark gap

3-4mm

Gas category countries of destination

CAT. I

2H

GB

CAT. I

3+

GB

This appliance complies with: European Council Directives Low voltage Directive

73/23/EEC, Gas Directive 90/396/EEC EMC Directive 89/336/EEC, CE Marking

Directive 93/68/EEC.

Advertising