Fireplace specifications – TOA Electronics BR-42 User Manual

Page 6

Advertising
background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

6

FIREPLACE SPECIFICATIONS

Figure 10

Figure 8

Figure 9

Step 3. Refer to fireplace drawings and specifi-
cations on pages 6 and 7 for framing dimensions
and details. Frame appliance enclosure as illus-
trated in

Figures 11 through 14 on page 8.

IMPORTANT: UNDER NO CIRCUMSTANCES
CAN THE FIREPLACE TOP SPACERS (

FIGURE

10 ) BE REMOVED OR MODIFIED, NOR MAY
YOU NOTCH THE HEADER TO FIT AROUND OR
BE INSTALLED LOWER THAN THE SPACERS.
THE HEADER MAY BE IN DIRECT CONTACT
WITH THE TOP SPACERS BUT MAY NOT BE
SUPPORTED BY THEM.

Note: The framed depth, 20

⁵⁄₈" (524 mm) from

a framed wall, must always be measured from
a finished surface. If a wall covering such as
drywall is to be attached to the rear wall, then
the 20

⁵⁄₈" (524 mm) must be measured from

the drywall surface. It is important that this
dimension be exact.

If the appliance is to be elevated above floor
level, a solid continuous platform must be
constructed.

The header may rest on the top metal spacers,
but must not be notched to fit around them.

Consult all local codes.

45"

(1143 mm)

31

⁹⁄₁₆"

(802 mm)

21

¹⁄₄"

(540 mm)

8

³⁄₁₆"

(208 mm)

Top View

Right Side

Gas Line

Access

Junction

Box

Combustion

Air Inlet

9

⁷⁄₈"

(251 mm)

43"

(1092 mm)

21

¹⁄₄"

(540 mm)

43"

(1092 mm)

21

¹⁄₄"

(540 mm)

Left Side

45"

(1143 mm)

Front

43"

(1092 mm)

7

³⁄₁₆"

(183 mm)

41"

(1041 mm)

2"

(51 mm)

12

¹⁄₂"

(318 mm)

22

⁵⁄₁₆"

(566 mm)

13

⁷⁄₁₆"

(341 mm)

8

³⁄₈"

(213 mm)

Fireplace Top Spacer

Fireplace

Top Spacer

Gas Line

Access

19"

(483 mm)

10"

(254 mm)

12

¹⁄₂"

(318 mm)

47"

(1194 mm)

1"

(25 mm)

38"

(965 mm)

Blocking

Metal Safety Strips

Metal Safety Strips

1

¹⁄₂"