Summary, Serial port setting, Command configuration – TOA Electronics RS-232C User Manual

Page 3

Advertising
background image

1. SUMMARY

The RS-232C protocol described in this document is designed to be used to control the
9000 Series Amplifier from a PC and/or remote controller. This specification applies to the
9000 Series firmware version 3.13 or later.

Settings that can be controlled are as follows:

•

Channel fader gain

•

Crosspoint gain (Mixer mode only)

•

Preset memory recall

•

Channel ON/OFF

•

Power ON/OFF

•

Tone control (Bass/Treble)

•

EQ settings (ON/OFF, Band number selection, Gain setting, Q setting, Center frequency setting)

•

Loudness compensation settings

•

Filter settings (High Pass Filter/Low Pass Filter)

•

Input sensitivity setting

•

Phantom power setting

Following values can be read from the 9000 Series Amplifier.

•

Channel name

When connecting the PC and/or remote controller to the 9000 Series Amplifier using this protocol,

set the 9000 Series Amplifier’s RS-232C port as follows:

Bit rate: 9,600/19,200/38,400/57,600 bps (Select the band rate depending on the

remote controller to be connected.) (See; Operating instructions of the 9000
Series Amplifiers.)

COMMANDLIST, COMMUNICATION EXAMPLES and PARAMETER TABLES are
available at the end of each section of this document.

2. SERIAL PORT SETTING

•

9,600/19,200/38,400/57,600 bps, 8 bits, non-parity, stop bit: 1, non flow control

•

Connector: D-sub 9 pins, straight cable

•

Signal line: No.2=TX, No.3=RX, No.5=Ground

3. COMMAND CONFIGURATION

•
• is in the range of 80H to FFH. and are in the range of 00H to 7FH.
• Data length (N) refers to the length of the subsequent data of Data 1 to Data N.
• If received data contains more byte data than the Data length, these exceeding data are

abandoned.

Page 3 of 24

Command

Data length

(N)

Data 1

Data 2

Data N

Data

D a t a

Command

Advertising