Jus' print rp-3200 user’s manual – TVS electronic RP-3200 User Manual

Page 25

Advertising
background image

Jus' Print RP-3200 User’s Manual

24

Important!

When connecting or disconnecting the power supply from the printer, be sure that the
following cautions are observed.
(1) Use a power supply (Limited Power Supply) of DC 24V±10% and more than 2.5A.
(2) Be careful about installing the printer in an area where there is noise.
(3) Take the appropriate measure to protect against electrostatic AC line noise, etc.

6-5. Environmental Requirements

(1) Operating
Temperature

5°C to 40°C

Humidity 10% to 90% RH (without condensation)

(2) Transport/Storage (except paper)
Temperature

-20°C to 60°C

Humidity

10% to 90% RH (without condensation)

6-6. Reliability

(1) MCBF

60 million lines (based on an average printing rate of 12.5% with paper

thickness in the range of from 65µm - 75µm)

35 million lines (based on an average printing rate of 12.5% with paper

thickness in the range of from 76µm - 150µm)

(2) Head Life

100 million pulses, 100Km

(3) Cutter Life 1.0 million cuttings (if the paper thickness is between 65 and 100µm)

6-7. Certification

(1) FCC PART15 CLASS A
(2) CE EMCD/LVD
(3) UL/cUL
(4) MIC
(5) RoHS

!

Advertising