SOMETHING NOT WORKING

Important: If you call out an engineer to a fault listed below, or to repair a fault caused by incorrect use or

installation a charge will be made, even if the appliance is under guarantee.
Before contacting your local Service Force Centre, check the following points:

Low ambient operation

During prolonged periods of low ambient temperatures,ie;10¡C and lower, the compressor on single

compressor fridge freezers can remain inoperative during this time .
This is due to the air temperature within the refrigerator compartment being maintained at 6¡C or under thus not

calling the thermostat to energise the compressor .

Symptom

No power to the appliance

The light does not come on

The temperature in the fridge or freezer section is

too high

The freezer door will not open

The compressor runs continously

Excessive frost and ice has built up

Noise
Water under the salad bin

Solution

Check there is power at the socket.

Check there is not a power cut by checking the

household lights.
Check the fuse has not blown.

Ensure that the bulb is correctly fitted.

Replace the bulb if it has blown.

Check the door light switch is not jammed.

Check the thermostat control knob in the fridge is

turned to the correct setting relative to ambient

conditions.
Check the ambient temperature is within the

applianceÕs operating limits of 10¡C to 32¡C.

Relocate the appliance if necessary.
Has door just been opened? If so leave for a few

minutes to allow the air pressure to equalise.
Adjust the thermostat control knob to give correct

temperature control. See ÒSetting the temperatureÓ.
Check that the doors are closed.

Large quantities of food have recently been placed in

the cabinet and/or door is frequently opened.

Check that air ventilation is not obstructed.

Ensure the doors are not left open.

Check that nothing is preventing the doors from

closing.
Is the door gasket intact and clean.

Has advised periodic defrosting been carried out.

Refer to normal operating sounds.
Check the drain hole is not blocked. (see

Maintenance and Cleaning).

15

TECHNICAL SPECIFICATIONS

POWER SUPPLY VOLTAGE AND FREQUENCY

220-240 V / 50 Hz

TOTAL POWER ABSORBED

160 W

AVERAGE DAILY UNITS ELECTRICITY *

1.40 kWh

GROSS CAPACITY

Fridge 214

l

Freezer

68 l

NET CAPACITY

Fridge 210

l

Freezer

55 l

STAR RATING

*

This figure is based on standard test results in accordance with European Standard EN 153.

Actual consumption will depend on how the appliance is used and where it is located.