4 procedure, 1 ac adapter detection threshold, 2 charger regulation voltage – Texas Instruments BQ2461X User Manual

Page 6: 3 charge current and ac current regultion (dpm)

Advertising
background image

Test Summary

www.ti.com

2.4

Procedure

2.4.1

AC Adapter Detection Threshold

1. Make sure EQUIPMENT SETUP steps are followed. Turn on PS#2.
2. Turn on PS#1

Measure

V(J5(SYS)) = 0 ± 500mV

Measure

V(TP(VREF)) = 0V ± 1000mV

Measure

V(TP(REGN)) = 0V ± 500mV

3. Increase the output voltage on PS#1 until D5 (PG) on but do not exceed 5V. Set the power supply #2

to 1.8V ± 100mVDC
Measure

V(J1(VIN)) = 4.5V ± 0.5V

Measure

V(J5(SYS)) = 4.5V ± 0.5V

Measure

V(TP(VREF)) = 3.3V ± 200mV

Measure

V(TP(REGN)) = 0V ± 500mV

Measure

D4 (/ACDRV) on, D5 (PG) on

2.4.2

Charger Regulation Voltage

1. Increase the voltage of PS#1 until V(J1(VIN)) = 24V ± 0.1V.

Measure

V(J5(BAT, GND)) = 0V ± 1V

2. Put JP5 on (Enable the charging).

Observe

D3 (CE) on.

Measure

Peak V(J5(BAT)) = 21.0V ± 1V (bq2461x)

Measure

Peak V(J5(BAT)) = 18.0V ± 1V (bq2463x)

Measure

V(TP(REGN)) = 6V ± 500mV

2.4.3

Charge Current and AC Current Regultion (DPM)

1. Take off JP5 (Disable the charging).
2. Connect the Load #2 in series with a current meter (multimeter) to J5 (BAT, GND). Make sure a

voltage meter is connected across J5 (BAT, GND). Turn on the Load #2. Set the output voltage to 12V
(bq2461x) or 2V (bq2463x).

3. Connect the output of the Load #1 in series with a current meter (multimeter) to J5 (SYS, GND). Make

sure a voltage meter is connected across J5 (SYS, GND). Turn on the power of the Load #1. Set the
load current to 3.0A ± 50mA but disable the load #1. The setup is now like

Figure 1

for HPA422. Make

sure Ibat = 0A ± 10mA and Isys = 0A ± 10mA.

4. Put JP5 on (Enable the charging).

Observe

D3 (CE) on

Measure

Ibat = 300mA ± 200mA (bq2461x)

Measure

Ibat = 125mA ± 60mA (bq2463x)

Observe

D7 (STAT1) on; D8 (STAT2) off.

5. Set the Load #2 output voltage to 16.5V.

Measure

Ibat = 3000mA ± 300mA

Observe

D7 (STAT1) on; D8 (STAT2) off.

6. Enable the output of the Load #1

Measure

Isys = 3000mA ± 200mA, Ibat = 1400mA ± 500mA, Iin = 4000mA ± 500mA

7. Turn off the Load #1.

Measure

Isys = 0 ± 100mA, Ibat = 3000mA ± 300mA.

8. Increase the Load #2 output voltage from 16.5V to 22V (61x) or 19V (63x).

Measure

Isys = 0 ± 100mA, Ibat = 0mA ± 100mA.

Observe

D7 (STAT1) off; D8 (STAT2) on.

9. Decrease the Load #2 output voltage back to 16.5V.

Observe

D7 (STAT1) on; D8 (STAT2) off.

6

bq2461x/bq2463x EVM (HPA422) Multi-Cell Synchronous Switch-Mode Charger

SLUU396A – January 2010 – Revised July 2010

Copyright © 2010, Texas Instruments Incorporated

Advertising
This manual is related to the following products: