0204

THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE
The cross-flow heat recovery core transfers heat between the two air streams.
It is easily removed for cleaning or service.
MOTORS AND BLOWERS
Each air stream has one centrifugal blower driven by a common PSC motor.
FILTERS
Washable air filters in exhaust and supply air streams.
MOUNTING THE HRV
Four threaded inserts at corners of case designed to accept four PVC reinforced polyester straps
that are supplied with the unit.
DEFROST
Damper defrost system; defrosts automatically as the outdoor temperature falls.
CASE
Twenty gauge prepainted galvanized steel (G60) for superior corrosion resistance. Insulated to
prevent exterior condensation. Drain connections two - 1/2" (12mm) OD.
WEIGHT
63 lbs. (28.7 kg)
SHIPPING WEIGHT
67 lbs. (30.4 kg)
CONTROLS
HRV System Control
HRV defaults to LOW SPEED when plugged in. HIGH SPEED option is accessible by connecting
remote controls to designated terminals inside electrical box of HRV.

Standard LOW SPEED SETTING can be increased by manipulating switches in electrical box.
OFF(Standby)/LOW or OFF/HIGH speed operation also available by manipulating switches.
OPTIONAL ACCESSORIES
99-132

20 Minute Fan Timer - (3 wire) 20 gauge wire (min.) 100’ length (max.)

99-186

Weather Hoods, 2 - 6" (150mm) c/w 1/4" (6mm) screen

99-116

Dehumidistat Ventilation Control - Dehumidistat with ON/OFF

99-130

Dehumidistat Control - Dehumidistat

All units conform to CSA and UL standards.

23.5"
(597)

22.5"
(572)

26.5"

(673)

*All Duct Connections 6" (150mm)

CONDENSATE DRAINS

DAMPER

BLOWERS

DEFROST

PORT

FRONT VIEW

TOP VIEW

SIDE VIEW

*NOTE: Front clearance
of 25 inches (635 mm)
is recommended
for servicing unit.

STALE AIR

TO OUTSIDE

FRESH AIR

FROM OUTSIDE

STALE AIR

FROM INSIDE

FRESH AIR

TO INSIDE

Warranty

Two year parts.

Fifteen year aluminum core.

*Sensible Efficiency - thermal **Latent Efficiency - moisture

Note: Effectiveness - based on temp. differential between the 2 airstreams
Efficiency - includes parasitic losses from fan and defrosting

Performance

Net supply air flow in cfm (L/s) against external static pressure

E.S.P

RNC25

(external static pressure)

[cfm (L/s)]

@ 0.1" (25 Pa)

214 (101)

@ 0.2" (50 Pa)

206 (97)

@ 0.3" (75 Pa)

193 (91)

@ 0.4" (100 Pa)

184 (87)

@ 0.5" (125 Pa)

170 (80)

Max.Sensible Effectiveness

69%

-13°F (-25°C) outdoor air

72°F (22°C) 40% RH indoor air

Test Parameters

127cfm (60L/s)

Sensible Effectiveness 32°F (0°C)

67%

*Sensible Efficiency 32°F (0°C)

60%

*Sensible Efficiency -13°F (-25°C)

59%

**Latent Efficiency 95°F (35°C)

0%

Total Efficiency 95°F (35°C)

20%

VAC @ 60HZ

120

WATTS / [email protected]” W.C.

182

WATTS / Low @.3” W.C.

70

Engineering Data - HRV