After-running time AT – During the start phase, the pump may repeatedly switch on and off for a
long time, especially systems with long solar loop. The after-run time AT can be changed from 0
(factory setting) to 9 minutes.


larm functions - User can enable the alarm function of the USDT 2004 in the ALARM
screen. Status of sensors and circulation pump can be viewed if alarm function is active.

A ON

Alarm function enable

A OFF

Alarm function disable


The status of the system can be monitored in the Stat Mode only if the corresponding feature is
active. The following example shows a system condition with a circulation problem:

CET OFF

Collector excess temp. cut-off active (no error occurred)

CET ON

No overheating

1 SHORT

Short circuit in sensor 1 wiring

2 SHORT

Short circuit in sensor 2 wiring

1 OPEN

Disconnection in sensor 1 wiring

2 OPEN

Disconnection in sensor 2 wiring

OK

System operates normal

NO CIRC

r T is more than 108

o

F in last 30 minutes

OK CIRC

Pump is running

CLEAR

Clears NO CIRC display after correction