Door reversal directions

Important

Before carrying out the operations described below
unplug the mains lead from the wall socket.
To carry out this reversal, proceed as follows:
1. Gently lay the fridge-freezer on its back with the top

held away from the floor by 5-8 cm (2-3 inches) of
packing.

2. Using a PHILLIPS screwdriver remove the top hinge.
3. Slide out the upper door from the middle hinge.
4. Unscrew the left levelling foot.

Unscrew the right levelling foot, hinge and refit them
on the left side.
Refit the other foot on the right side.

5. Slide out the lower door from the middle hinge.
6. Remove the middle hinge.
7. Remove the plastic plugs from the screw holes of the

new top & middle hinge location and refit them in the
holes on the opposite side.

8. Remove the screws from the new location of the

bottom hinge and refit them in the free holes on the
opposite side.

9. Refit the middle hinge as shown in Fig., i.e. up-side-

down with respect to the previous position.

10.Replace the lower & upper door making sure that the

pins of the middle hinge fit into the corresponding
bushing on the door.

11. Replace the bottom hinge on the left side of the

lower base of the cabinet (the fastening holes are
already provided). Refit the top hinge.

Important

The central hinge is designed to allow a certain amount
of side clearance (play), i.e. approx. 3 mm horizontally,
which makes it easy to line up the two doors by
proceeding as follows:
Loosen the two screws securing the hinge to the
cabinet.
Carefully position the hinge until the two doors are
perfectly aligned, then firmly screw down the hinge in its
new setting (position).

Reversing door handles

Remove the handle by unscrewing the two fastening
screws.
Remove the plastic plugs from the screw holes of the
new handle location and refit them in the free holes
onthe opposite side;
Refit the handle upside-down, on the opposite side of
the door.

Attention

After completion of the door reversing operation, check
that the door gasket adheres to the cabinet. If the
ambient temperature is cold (i.e. in Winter), the gasket
may not fit perfectly to the cabinet. In that case, wait for
the natural fitting of the gasket or accelerate this
process by heating up the part involved with a normal
hairdrier.