6

The gas control valve is located in the lower
control compartment. To access the valve
open the lower control compartment door
(

Figure 9 ).

The regulator has a 3/8" NPT thread inlet port
and is fitted with a 3" (76 mm) long nipple,

³⁄₈"

NPT on both ends. Plan the connections ac-
cordingly.

We recommend that the gas line be routed for
the right side of the appliance to ensure ad-
equate access to the rear lower compartment
for installation and servicing of the optional
FAB-1100 blower.

Figure 6

Figure 8

37-1/4"

(946 mm)

37"

(940 mm)

15-1/2"

(394 mm)

Figure 9

Secure all joints tightly using appropriate
tools and sealing compounds (ensure pro-
pane resistant compounds are used in
propane applications).

Turn on gas supply and test for gas leaks,
using a gas leak test solution (also referred to
as bubble leak solution).

Note: Using a soapy water solution (50% dish
soap, 50% water) is an effective leak test
solution but it is not recommended, because
the soap residue that is left on the pipes/
fittings can result in corrosion over time. Never
use an open flame to check for leaks.

Figure 4

37" (940mm)

15-1/2"

(394mm)

Outside Wall

Back Wall of

Chase/Enclosure

Including Finishing

Materials If Any.

Figure 5

37" (940mm)

58-1/2" (1486mm)

13-1/2"

(343mm)

29"

(737mm)

41"

(1041mm)

Back Wall of

Chase/Enclosure

Including Finishing

Materials If Any.

Step 2. Route a 1/2" (13 mm) gas line along the
left or right side framing (

Figure 7 ).

All appliances have a 3" long 3/8" NPT nipple
installed at the regulator. To quickly and easily
complete the gas line routing, use the gas flex
line kit, Model GFLV.

Step 3. Position appliance into prepared fram-
ing, secure with 6d nails at the nailing flange
along each side.

Step 4. Connecting Gas Line – Make gas line
connections. All codes require a shut-off valve
mounted in the supply line.

Figure 8 illustrates

two methods for connecting the gas supply.
Installation methods and materials must be in
compliance with local codes.

3"

(76 mm)

7"
(178 mm)

Figure 7

Gas Stub

1/2" x 3/8" Flare

Shut-Off Valve

3/8" Flex Tubing

3/8" NPT x 3/8"

Flare Fitting

3/8" Nipple, Standard

with all Units

3/8" Union

3/8" Close Nipple

3/8" Shut-Off Valve

1/2" x 3/8" Reducer

Gas Valve

Gas Flex Line Kit, Model GFLV

Control Valve

(Standard)

Lower Control

Compartment Door