Trane XT500C User Manual

Page 62

Advertising
background image

62

Pub. No. 22-5128-02

69-1216

Troubleshooting Guide (continued).

Symptom

Possible Cause

Action

System on indicator
(flame=heat, snowflake=
cool) is lit, but no warm or
cool air is coming from
the registers.

Heating/cooling equipment turns on
the fan when the equipment has
reached the setpoint.

Wait a minute after seeing the flame or snowflake and then

check the registers.

System on indicator
reads Filter and backlight
is flashing.

Filter expired.

Refer to the Filter Indication section.

Outdoor temperature not
displayed or is incorrect.

Filter expired.

Press

twice for outdoor temperature when filter

expiration shows on display.

Refer to the Filter Indication section.

Installer did not activate this option.
Outdoor sensor is connected
incorrectly.

Contact installer or service technician.

LED is lit.

System switch is set to Em. Heat.

Move switch to Heat or Auto

Compressor failure.

Contact service technician.

Advertising