Parameter

Parameter

Modbus Start

3 Ш

3 Ш

1 Ш

1 Ш

Number

Address Hex

4 wire 3 wire 3 wire 2 wire

High Byte Low Byte

30001

1

Volts 1 (L1 – N 4W or L1 – L2 3W)

00

00

✓

✓

✓

✓

30003

2

Volts 2 (L2 – N 4W or L2 – L3 3W)

00

02

✓

✓

✓

X

30005

3

Volts 3 (L3 – N 4W or L3 – L1 3W)

00

04

✓

✓

X

X

30007

4

Current 1

00

06

✓

✓

✓

✓

30009

5

Current 2

00

08

✓

✓

✓

X

30011

6

Current 3

00

0A

✓

✓

X

X

30013

7

Watts Phase 1 - Integra 1540 only

00

0C

✓

X

✓

✓

30015

8

Watts Phase 2 - Integra 1540 only

00

0E

✓

X

✓

X

30017

9

Watts Phase 3 - Integra 1540 only

00

10

✓

X

X

X

30019

10

VA Phase 1 - Integra 1540 only

00

12

✓

X

✓

✓

30021

11

VA Phase 2 - Integra 1540 only

00

14

✓

X

✓

X

30023

12

VA Phase 3 - Integra 1540 only

00

16

✓

X

X

X

30025

13

var Phase 1 - Integra 1540 only

00

18

✓

X

✓

✓

30027

14

var Phase 2 - Integra 1540 only

00

1A

✓

X

✓

X

30029

15

var Phase 3 - Integra 1540 only

00

1C

✓

X

X

X

30031

16

Power Factor Phase 1 - Integra 1540 only

00

1E

✓

X

✓

✓

30033

17

Power Factor Phase 2 - Integra 1540 only

00

20

✓

X

✓

X

30035

18

Power Factor Phase 3 - Integra 1540 only

00

22

✓

X

X

X

30037

19

Phase Angle Phase 1 - Integra 1540 only

00

24

✓

X

✓

✓

30039

20

Phase Angle Phase 2 - Integra 1540 only

00

26

✓

X

✓

X

30041

21

Phase Angle Phase 3 - Integra 1540 only

00

28

✓

X

X

X

30043

22

Volts Ave

00

2A

✓

✓

✓

✓

30047

24

Current Ave

00

2E

✓

✓

✓

✓

30049

25

Current Sum - Integra 1540 only

00

30

✓

✓

✓

✓

30053

27

Watts Sum

00

34

✓

✓

✓

✓

30057

29

VA Sum

00

38

✓

✓

✓

✓

30061

31

var Sum

00

3C

✓

✓

✓

✓

30063

32

Power Factor Ave

00

3E

✓

✓

✓

✓

30067

34

Average Phase Angle - Integra 1540 only

00

42

✓

✓

✓

✓

30071

36

Frequency

00

46

✓

✓

✓

✓

30073

37

Wh Import

00

48

✓

✓

✓

✓

30077

39

varh Import

00

4C

✓

✓

✓

✓

30085

43

W Demand Import

00

54

✓

✓

✓

✓

30087

44

W Max. Demand Import

00

56

✓

✓

✓

✓

30105

53

A Demand

00

68

✓

✓

✓

✓

30107

54

A Max. Demand

00

6A

✓

✓

✓

✓

30201

101

V L1-L2 (calculated)

00

C8

✓

X

✓

X

30203

102

V L2-L3 (calculated)

00

CA

✓

X

X

X

30205

103

V L3-L1 (calculated)

00

CC

✓

X

X

X

30207

104

Average Line to Line Volts

00

CE

✓

X

✓

X

30225

113

Neutral Current

00

E0

✓

X

✓

✓

30235

118

THD Volts 1 - Integra 1540 only

00

EA

✓

✓

✓

✓

30237

119

THD Volts 2 - Integra 1540 only

00

EC

✓

✓

✓

X

30239

120

THD Volts 3 - Integra 1540 only

00

EE

✓

✓

X

X

30241

121

THD Current 1 - Integra 1540 only

00

F0

✓

✓

✓

✓

30243

122

THD Current 2 - Integra 1540 only

00

F2

✓

✓

✓

X

30245

123

THD Current 3 - Integra 1540 only

00

F4

✓

✓

X

X

30249

125

THD Voltage Mean - Integra 1540 only

00

F8

✓

✓

✓

✓

30251

126

THD Current Mean - Integra 1540 only

00

FA

✓

✓

✓

✓

30255

128

Power Factor (+Ind/-Cap)

00

FE

✓

✓

✓

✓

58