Tc9457f, Electrical characteristics, Ta = 25°c) – Toshiba TC9457F User Manual

Page 10: Ta = 25, C, v, 5 v, 2v, 2 v, v, 1 v, unless otherwise specified)

Advertising
background image

TC9457F

2002-10-21

10

Maximum Ratings

(Ta = 25°C)

Characteristics Symbol

Rating

Unit

Power supply voltage

V

DD

−0.3~6.0 V

Input voltage

V

IN

−0.3~V

DD

+ 0.3

V

Power dissipation

P

D

1400

mW

Operating temperature

T

opr

−40~85 °C

Storage temperature

T

stg

−65~150 °C

Electrical Characteristics

(Ta = 25

°

C, V

DD

= MV

DD

= AV

DD

= DV

DD

= XV

DD

= 5 V,

2V

REF

= P2V

REF

= 4.2 V, V

REF

= PV

REF

= 2.1 V, unless otherwise specified)

MV

DD

(CPU unit power supply)

Characteristics Symbol

Test

Circuit

Test Condition

Min

Typ.

Max

Unit

MV

DD1

―

When CPU and CD operating.
However,
MV

DD

≥ V

DD

(Note

5)

4.5 5.0 5.5

MV

DD2

―

When CPU operating
(CD powered off, 4.5 MHz
crystal connected)

(Note 5)

4.5 5.0 5.5

Operating supply voltage

MV

DD3

―

When CPU operating (CD
powered off, 75 kHz crystal
connected) (Note

5)

2.7 5.0 5.5

V

Memory retention voltage range

MVHD

―

When crystal oscillator stopped
(CKSTP instruction executed)
(Note

5)

2.0 ~ 5.5 V

MV

DD1

―

When CPU operating
(XI = 16.9344 MHz crystal
connected)

― 1.0 2.0

MV

DD2

―

When CPU operating(MXI =
4.5 MHz crystal connected)

― 2.0 4.0

MV

DD3

―

When CPU operating (MXI =
75 kHz crystal connected)

― 0.75 2.0

Operating supply current

MV

DD4

―

Standby mode (only crystal
oscillating, 4.5 MHz or 75 kHz
crystal connected)

― 0.5 15

mA

Memory retention current

MIHD

―

When crystal oscillator stopped
(CKSTP instruction executed)

― 0.1 1.0 µA

f MXT1

―

Rf = 1 MΩ, Rout = 0 Ω,
Ci = Co = 30 pF

(Note 5, 6)

― 4.5 ― MHz

Crystal oscillation frequency

f MXT2

―

Rf = 10 MΩ, Rout = 100 kΩ,
Ci = Co = 15 pF,
MV

DD

= 2.7~5.5 V (Note 5, 6)

― 75 ― kHz

Crystal oscillation start time

tst

―

Crystal oscillation fmxt = 75
kHz

―

― 1.0 s

Note 5: Guaranteed at V

DD

= MV

DD

= 4.5 to 5.5 V and Ta = −40 to 85°C

Note 6: Consider the crystal resonator used in your system when determining constants, etc.