TroubleshooTing

System Will Not Operate

1) Plugged into dead outlet
2) Blown fuse or breaker
3) Defective power cord
4) Defective switch
5) Loose wiring
6) Improper connection

1) Plug into live grounded outlet
2) Replace fuse or breaker
3) Replace power cord
4) Replace switch
5) Properly connect wiring
6) Press tightly into outlet

CondiTion

Cause

CorreCTion

Vacuum Motor Will Not Run

1) Main power not activated
2) Loose wiring
3) Defective vacuum switch
4) Defective vacuum motor

1) Active main power switch
2) Tighten and connect wiring
3) Replace vacuum switch
4) Replace vacuum motor

Pump Will Not Run

1) Main power not activated
2) Defective pump switch
3) Loose wiring
4) Plugged spray jet
5) Lint buildup in hose coupling
6) Kink in solution hose
7) Defective pump

1) Activate main power
2) Replace pump switch
3) Tighten and connect wiring
4) Remove blockage
5) Disassemble and remove lint
6) Straighten hose
7) Replace pump

Pump Runs But Will Not
Spray/Weak Spray

1) Solution tank empty
2) Obstructed spray jet
3) Obstructed hose coupling
4) Obstructed solution filter
5) Hose damage
6) Pump components

wearing out

1) Refill solution tank
2) Remove blockage
3) Remove obstruction
4) Clean filter
5) Replace necessary hose
6) Replace pump

Loss of Vacuum Suction

1) Recovery dome not seated
2) Obstruction in vac hose
3) Obstruction in wand
4) Screen filter clogged
5) Recovery dome needs gasket

1) Re-seat for better seal
2) Remove obstruction
3) Remove obstruction
4) Remove debris
5) Replace dome gasket