Connecting to gas supply, Fitting the stability bracket – Tricity Bendix L55M2 User Manual

Page 31

Advertising
background image

31

Connecting to gas supply

This appliance is designed to be installed

with an appliance flexible connection only.

Supply piping should not be less than R

3

/8.

Connection is made to the Rc ½ (½” B.S.P.)

female threaded entry pipe located just

below the hotplate level on the rear left hand

side of the appliance.

NOTE: ONLY LIQUID

SEALANTS TO BE USED WHEN INLET

GAS PIPE IS FITTED I.E.: DO NOT USE

P.T.F.E. SEALANT TAPE. Carry out a gas

tightness test after connecting to the gas

supply. The gas bayonet connector must be

fitted in the shaded area indicated in Fig.3.

Take into account that it must be possible to

pull the appliance forward sufficiently.

Ensure the hose does not become trapped

when pushing the appliance into position.
IMPORTANT: FLEXIBLE TUBING USED

MUST COMPLY WITH BS.669 CURRENT

EDITION.
LPG Flexible connections must be a type

suitable for L.P.G and capable of operation

up to 50 mbar and carry a red stripe, band or

label.

Fitting the stability bracket

It is recommended that if the appliance is to

be installed with a flexible supply pipe, a

stability bracket be fitted and is available

from your supplier (see Important Safety

Requirements). These instructions should

be read in conjunction with any leaflet

packed with the stability bracket.
1. Place the appliance in its intended

position and level appliance.

2. Mark off 277mm from the left hand side

of the appliance as shown in dimension

'A', Fig

4a. This is the centre line of the

fixing bracket.

Fig.3

.

48

7m

m

(B

)

277mm

100mm

20mm

(A)

(C)

Fig.4a.

Fig.4b.

Advertising