Toshiba C-DR0101 User Manual

Page 19

Advertising
background image

A L A R M R E C S E T T I N G

A L A R M S E T T I N G

[ V A L I D ]

A L A R M I N M O D E

[ L E V E L ]

P R E – A L A R M

[ 0 0 S E C ]

A L A R M P E R I O D

[ 1 M I N ]

P O S T – A L A R M

[ 0 0 S E C ]

P I C T U R E Q U A L I T Y

[ L E V E L 3 ]

A U D I O

[ O N ]

R E C I N T E R V A L

[ 1 / 3 0 S E C ]

B U Z Z E R

[ O N ]

A L A R M O U T

[ D U R I N G R E C ]

19

Setting Value

Contents

Setting Item

ALARM SETTING

ALARM IN MODE

(Alarm Input Mode)

PRE-ALARM

ALARM PERIOD

POST-ALARM

PICTURE QUALITY

AUDIO

REC INTERVAL

(Recording Interval)

BUZZER

ALARM OUT (Alarm

Output Periods )

VALID :

Validates alarm settings. (Alarm standby mode)

VAL REC : Validates alarm settings only during recording.

INVALID : Invalidates alarm settings. (Rejects alarm inputs.)

EDGE : Performs recording during preset Pre-alarm and Alarm

Recording periods

LEVEL : Performs recording during preset Pre-alarm Recording, Alarm

input, and Post-alarm Recording periods.

Performs retroactive recording to a preset time period before alarm

activation.

Performs recording during a preset alarm input period following alarm

activation when the Alarm Input Mode is set to EDGE. (Refer to p. 20;

"About the Alarm Input Mode")

Performs recording during a preset Post-alarm recording period following

the end of alarm activation when the alarm input mode is set to "LEVEL."

LEVEL1 : Angle of view 720 x 240; file size : 64KB (High Picture Quality)

LEVEL2 : Angle of view 720 x 240; file size : 40KB

LEVEL3 : Angle of view 720 x 240; file size : 32KB

LEVEL4 : Angle of view 720 x 240; file size : 24KB

LEVEL5 : Angle of view 720 x 240; file size : 16KB

(Standard Picture Quality)

ON:

Records audio sound simultaneously during recording.

OFF: Records no audio sound during recording.

Sets the Recording intervals.

Setting the Disk Mode of Disk Settings to "MIRRORING" limits the

maximum recording interval to 1/30 second. Even if set to "1/60 SEC", the

actual recording interval is 1/30 second, and the "1/30 SEC "indication is

displayed on the screen (C-DR0101, C-DR0105)

ON:

Sounds a buzzer when an alarm is activated. Pressing the Buzzer

Reset key stops buzzer operation.

OFF: Sounds no buzzer during alarm activation.

The Alarm Output terminal shorts to ground during a set period of time

following alarm activation.

VALID / VAL REC / INVALID

EDGE / LEVEL

00SEC/ 10SEC/ 15SEC/ 20SEC /

30SEC/ 1MIN/ 2MIN/ 5MIN

10SEC/ 15SEC/ 20SEC/ 30SEC/

1MIN/ 2MIN/ 3MIN/ 4MIN/ 5MIN/

10MIN

00SEC/ 10SEC/ 15SEC/ 20SEC/

30SEC/ 1MIN/ 2MIN/ 5MIN

LEVEL1 / LEVEL2 / LEVEL3 /

LEVEL4 / LEVEL5

ON / OFF

1/60SEC / 1/30SEC / 1/15SEC /

1/10SEC / 1/5SEC / 1/3SEC /

1/2SEC / 1SEC /

ON / OFF

DURING REC / 1SEC

• Move the cursor with the (

) or (

) key, and change setting values

with the (

) or (

+

) key.

• Confirm the setting with the Menu key, and return to the previous

screen.

• Each setting item and its setting value and contents are as shown in

the table below.

7.5.3. Alarm Recording Settings

Alarm Recording has two Alarm Input modes "EDGE" and "LEVEL" and valid setting items differ depending on
each mode.

Alarm Mode set to "EDGE" : Alarm recording time settings are valid.

Post-alarm time settings are invalid.

Alarm Mode set to "LEVEL" : Alarm recording time settings are invalid.

Post-alarm time settings are valid.

(For more information, Refer to p. 20; "About the Alarm Input Mode.")

* The underlined contents are factory-preset values.

Advertising