Startup, Electrical instructions – True Manufacturing Company TCGG-72-S User Manual

Page 11

Advertising
background image

............ www.truemfg.com ............

True Food Service Equipment, Inc.

9

9

INSTALLATION / OPERATION INSTRUCTIONS

A. The compressor is ready to operate. Plug in the unit.
B. Check the temperature control setting in the upper

left of the cabinet backside. The setting should be

at #5 to maintain an approximate 38˚F (3.3˚C). Set

defrost time clock to the correct time of day.

NOTE

Excessive tampering with the control is not recommended

as this can lead to service difficulties. Should it ever

become necessary to order a replacement temperature

control, be sure it is ordered from a dealer or recommended

parts stocking service company.
C.
Verify that the cabinet lights are working. Deli cases

are shipped with light switches in the “on” position.

The toggle switch is located upper left corner at the

rear.

NOTE

If the deli case is disconnected or shut off, wait five minutes

before starting again.

RECOMMENDATION
Before loading product we recommend you run your TRUE

unit empty for two to three days. This allows you to be sure

electrical wiring and installation are correct and no shipping

damage has occurred. Remember, our factory warranty

does not cover product loss!
REPLACEMENT PARTS

TRUE maintains a record of the cabinet serial number for

your unit. If at any time during the life of your display case,

a part is needed, you may obtain this part by furnishing

the model number and serial number to the company from

whom you purchased the cabinet. Call Toll-Free: (800)-424-

TRUE (Direct to Parts Department). (800)-325-6152 (U.S.A.

& Canada only) or call: (636)-240-2400.

STARTUP

A. Before your new unit is connected to a power supply,

check the incoming voltage with a voltmeter. If

anything less than 100% of the rated voltage for

operation is noted, correct immediately.

B. All units are equipped with a service cord, and must

be powered at proper operating voltage at all times.

Refer to cabinet data plate for this voltage.

TRUE requires that a sole use circuit be dedicated for the

unit. Failure to do so voids warranty.
WARNING

Compressor warranties are void if compressor burns out

due to low voltage.
WARNING

Power supply cord ground should not be removed!
WARNING

Do not use electrical appliances inside the food storage

compartments of the appliances unless they are of the

type recommended by the manufacturer.

NOTE

To reference wiring diagram - Remove front louvered grill,

wiring diagram is positioned on the inside cabinet wall.

ELECTRICAL INSTRUCTIONS

Curved Glass Deli Cases

Deli cases are equipped with a service receptacle

(found on the upper left cabinet backside),

No electrical load greater that 4.0 amps should be

connected to it. If the electrical load is greater that

4.0 amps, it should be wired separately or a larger

lead cord should be wired in place of the provided

lead cord. Use a cord with a 20 amp male plug

(NEMA-5-20P).