2 quick start list for platform – Texas Instruments TPA6030A4 User Manual

Page 16

Advertising
background image

Quick Start List for Platform

2-4

Quick Start

2.2

Quick Start List for Platform

Follow these steps when using the TPA6030A4EVM with the TI Plug-N-Play
audio amplifier evaluation platform (see the platform user’s guide, SLOU011,
for additional details). Numbered callouts for selected steps are shown in
Figure 2–1 and Figure 2–2:

Note:

The TI Plug-N-Play platform sends the input signal to both the HP and LINE
inputs automatically, and only to the positive inputs. To fully take advantage
of the TPA6030A4 differential input as well as the input mode selectable mux,
the EVM should be used in a stand-alone fashion.

-

Platform Preparations

1) Ensure that all external power sources are set to OFF and that the platform

power switch S1 is set to OFF.

2) Install a TPA6030A4 module in platform socket U2, taking care to align the

module pins correctly.

3) Use switch S2 to select or bypass the signal conditioning EVM (U1).

4) Set jumper JP6 to select the Mode control input.

5) Remove jumper JP5.

Table 2–3. Platform Jumper and Switch Settings for the TPA6030A4

EVM

JP5

JP6

JP7

JP8

S2

S3

P-N-P Platform

Off

Mode

X

Hi

Note 4

X

Notes:

1) X = Don’t care
2) ON = Shunt installed

3) OFF = Open

4) Set S2 to ON when signal conditioning board is installed in U1; set S2

to OFF when no signal conditioning board is installed.

-

Power Supply

6) Select and connect an external regulated power supply (ensure power

supply is turned OFF) set from 7 V to 15 V to platform V

CC

power input

connector J1, taking care to observe marked polarity. Jumper the
appropriate power input.

-

Inputs and Outputs

7) Ensure that the audio signal source level is set to minimum.

8) Connect the audio source to left and right RCA phono jacks J3 and J5 or

stereo miniature phone jack J4.

9) Connect speakers to left and right RCA jacks J7 and J9 or to stripped wire

speaker connectors J8.

Advertising