Communication parameters, Specifications, Warranty – Toshiba RS-485 User Manual

Page 10

Advertising
background image

9

9

6.Communication parameters

Function

Parameter

Adjustable range

Default value

Communication speed

F800

0
1
2
3

:
:
:
:

1200bps
2400bps
4800bps
9600bps

3

Parity

F801

0
1
2

:
:
:

NONE
EVEN
ODD

1

ASD number

F802

0~63
(0~31 in case that ASD has a
CPU whose version is V104 or
V103)
Note) Do not assign the same
ASD number to more than one
ASD in the same system.

0

Communication error trip time(s)

F803

0~100
(0:OFF, 1~100)

0

7.Specifications

Item

Specifications

Part number

RS4001Z-0

Service environment

Indoors. Altitude of less than 1000m (3280 ft).
Must not be exposed to direct sunlight, subjected to corrosive and/or
explosive gases, vapor, dust, chips, cutting oil, grinding agent, etc.

Ambient temperature

From -10

°C to +50°C (14°F to 104°F)

Storage temperature

From -25

°C to +65°C (-13°F to 149°F)

Relative humidity

20 to 90% (no condensation allowed)

Vibration

5.9m/s

2

or less

Cooling system

Self-cooling

8.Warranty

The RS-485 Option Unit is covered under warranty for period of 12 months from the date of installation,
but not to exceed 18 months from the date of shipment from factory. For further warranty or service
information, please contact Toshiba International Corporation.