TurboChef Technologies, Inc. C Series

8 - 9

# of

LED

Flashes

Fault

Description

Fault Cause

Corrective Action

9

Negative Slope

•

Conflicting parameter values

•

Adjust values of parameters P–50

through P–54

•

Phase U

•

Phase V


Ground Short

•

Phase W

•

Verify output wiring is correct

•

Verify output phase is not

grounded

•

Verify motor is not damaged

•

Phase U-V

•

Phase U-W

10

Phase to Phase

Short

•

Phase V-W

•

Verify output wiring is correct

•

Verify motor is not damaged

11

Checksum Failure

•

Parameter value out of range

•

Load default parameter values (P–

60=1), then cycle power. If fault
persists, replace drive.

12

Microprocessor

Fault

•

Internal processor error

•

Cycle power. If fault persists,

replace drive.