ISSUE

RESOLUTION

F2: Cook Temperature

Low

1. Verify the high-limit thermostat is not tripped.

†

If high-limit is tripped, reset and allow the oven to warm up.

†

If high-limit is not tripped, follow the instructions below.

High-limit thermostat is not tripped.

Place a small water load in a microwave/heat-resistant container

(approx. 275 ml) in the oven and place the oven in

TEST MODE

. Press

the

MGTRON

key to actuate the microwave. While holding down the

MGTRON

key, watch the CC and IR temperatures. If either temperature

bounces substantially, there may be a noise (EMI) problem.

To correct this problem, examine the wire routing for each

thermocouple wire. If the wires are routed near any high voltage

components such as the magnetron or high voltage transformers, re-

route the wires. If this does not correct the problem, verify that both

magnetrons are securely mounted. Call Technical Support for further

details at 800.90

TURBO

or +1 214-379-6000

.

23