4 tape drive operation, 1 front led indicators, 2 tape cartridge operation – Tandberg Data LTO-2 HH User Manual

Page 17

Advertising
background image

Tandberg LTO HH Installation and User Manual

13

4 Tape Drive Operation

4.1 Front LED Indicators

Figure 4.1 Status indicators (LEDs)

Drive State

READY LED
(Green)

ACTIVITY LED
(Green)

CLEAN LED
(Amber)

FAULT LED
(Amber)

LED-test.
The LEDs are turned ON in sequence

Power-On Self-Test
Starts in parallel with the LED-test .


ON

Flashing in
about 12 sec


ON

After 12 sec:
Flashing during
cartridge load


ON

OFF


ON

OFF

Cartridge not loaded.

OFF

OFF

ON / OFF

OFF

Cartridge loaded, no activity

ON

OFF

ON / OFF

OFF

Cartridge loaded, activity

ON

Flashing

ON / OFF

OFF

Cleaning

OFF

Flashing

ON

OFF

Cartridge loading or unloading

OFF

Flashing

ON / OFF

OFF

Unrecoverable drive failure

ON / OFF

OFF

ON / OFF

Flashing

Over temperature

OFF

OFF

ON / OFF

ON

Media Error (wrong, write protected or
harmed media)

OFF

Flashing

ON / OFF

Flashing

Table 4.1 Front LED behaviour during normal operation

See

Appendix A

for more information on LED operation

4.2 Tape Cartridge Operation

Use only certified quality cartridges for the Tandberg LTO HH Tape Drives. Do not use worn or
audibly noisy cartridges. Cartridges which repeatedly require rewriting of large numbers of data-
blocks per track should also be rejected.

Advertising