Oil nozzle capacity chart – Thermo Products OH6FA072DV4R User Manual

Page 9

Advertising
background image

All installations and services must be performed by qualified service personnel.

6

G. BURNER SPECIFICATIONS AND APPLICATIONS

FURNACE
MODEL

THERMO
PRIDE’S
BURNER
SPEC NO.

*
INS

BECKETT
BURNER
MODEL &
TUBE
LENGTH

HEAD STATIC

PLATE

MAXIMUM
NOZZLE
SIZE**

SHIPPED
NOZZLE
SIZE

OIL
PUMP
PRESSURE
(PSIG)

OH6FA072D**B

TP2501 N AFG-4.5” F3 3-3/8 0.75X80

° H

0.60X80

° H

120



The optional BF3 Riello flame retention oil burner can be used with OH6.

FURNACE
MODEL

THERMO
PRIDE’S
BURNER
SPEC NO.

*
INS

RIELLO
BURNER
MODEL &
TUBE
LENGTH

HEAD STATIC

PLATE

MAXIMUM
NOZZLE
SIZE**

SHIPPED
NOZZLE
SIZE

OIL
PUMP
PRESSURE
(PSIG)

OH6FA072D**R

C8511325 S BF3-4.5” N/A N/A 0.70X80

° H

0.60X80

° H

140


* INSULATOR S = SLEEVE OR N = NONE

THE NOZZLE SIZE GIVES THE NOMINAL FLOWRATE, IN GPH, FOLLOWED BY THE SPRAY
ANGLE, IN DEGREE’S, AND THE SPRAY PATTERN, EITHER “H” FOR HOLLOW CONE OR “S”
FOR SOLID CONE. FOR EXAMPLE, A NOZZLE RATED AT 0.65 GPH @ 100 PSIG THAT PROVIDES
AN 80° SPRAY ANGLE AND A HOLLOW SPRAY PATTERN WOULD BE ABBREVIATED IN THE
TABLE AS “0.65 X 80

°

H”.


For more specific burner information, contact Thermo Products, LLC. P.O. Box 217, North Judson, IN 46366.
Phone 574-896-2133.


All rates shown achieved with 120 PSIG pump pressure for Beckett and 140 PSIG pump pressure for Riello.
* Based on #2 domestic heating fuel oil having heating value of 140,000 BTU per gallon.
** Based on thermal efficiency of 84%-85%.

OIL NOZZLE CAPACITY CHART

NOZZLE SIZE
(GPH)


UNITS

Beckett Riello

EQUIVALENT HEAT
INPUT RATE*
(BTU/HR)

EFFECTIVE HEATING
CAPACITY**
(BTU/HR)

OH6FA060D*** .50

.50 70,000

60,000

OH6FA072D*** .60

.60

85,000

73,000

OH6FA090D*** .75

.70

106,250

90,000

Advertising