Technical specification, Rj-11c connector specification, Troubleshooting – Transition Networks SAPTF33xx-100 User Manual

Page 5: Unit a (telephone emulation), Unit b (central office emulation)

Advertising
background image

Technical Specification

For use with Transition Networks Model SAPTF33xx-1xx or equivalent

Standards

FCC Part 68, TBR21

Dimensions

3.6" x 4.5" x 1.8" (91 mm x 115 mm x 45 mm)

Shipping Weight

1 lb. (0.45 kg) (approximate)

Power Consumption

7.0 watts

Power Supply

12VDC, 0.8 Amp (North America, Europe, UK)
12VDC, 1.25 Amp (Latin Am., Japan, N.Z., Australia, S. Africa)
The external power supply provided with this product is UL
listed by the power supply’s manufacturer.

MTBF

47,000 hours (MIL217F2 V5.0) (MIL-HDBK-217F)
115,000 hours (Bellcore7 V5.0)

Environment

Tmra*:

0° to 50°C (32° to 122° F )

Storage Temp:

-15° to 65°C (-4° to 122°F)

Humidity:

5 to 95%, non condensing

Altitude:

0 to 10,000 feet

Warranty

Lifetime

*Manufacturer’s rated ambient temperature.

The information in this user’s guide is subject to change. For the most up-to-date
information on the SAPTF33xx-1xx media converter, view the user’s guide on-line at:
www.transition.com.

Product is certified by the manufacturer to comply with DHHS Rule 21/CFR, Subchapter J
applicable at the date of manufacture.

CAUTION: Visible and Invisible Laser Radiation When Open. Do Not Stare Into Beam Or
View Directly With Optical Instruments.

CAUTION: Use of controls, adjustments or the performance of procedures other than
those specified herein may result in hazardous radiation exposure.

12

SAPTF33xx-1xx

24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600

RJ-11C Connector Specification

Unit A (Telephone Emulation)

Connector:

RJ-11C

Impedance:

600

REN:

0.4 B

Loop Current:

10 to 100 mA

Insertion Loss:

0.0 ± 1.0 dB at 1000 Hz
(When both ports are terminated at 600

Ω.)

Unit B (Central Office Emulation)

Connector:

RJ-11C

Impedance:

600

Battery Source:

48 VDC +/- 5V

Ringing Supply:

90 Vp-p

RIng Frequency:

15-30 Hz (Reproduces the frequency detected by Unit A.)

Ring Cadence:

Reproduces the cadence detected by Unit A.

Insertion Loss:

0.0 ± 1.0 dB at 1000 Hz
(When both ports are terminated at 600

Ω.)

13

[email protected]

Click the “Transition Now” link for a live Web chat.

Troubleshooting

1.

Is the PWR (power) LED illuminated?
NO

Is the power adapter the proper type of voltage and cycle frequency
for the AC outlet? (See “Power Supply” on page 12.)

Is the power adapter properly installed in the media converter and in
the outlet?

Does the external power source provide power?

Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.

YES

Proceed to step 2.

2.

Is the SDF (signal detect fiber Link) LED illuminated?
NO

Check the fiber cables for proper connection.

Verify that the TX and RX cables on the first media converter are
connected to the RX and TX ports, respectively, on the second media
converter.

Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.

Advertising