HE104MAN-V8 Manual

Tri-M Engineering

Tel:

800.665.5600, 604.945.9565

1407 Kebet Way, Unit 100

Fax:

604.945.9566

Port Coquitlam, BC V3C 6L3

E-mail:

[email protected]

Canada

Web site:

www.tri-m.com

28

‘D1 = 0, D0 = 0 channel 0 input, pin3 of connector CN3

‘D1 = 0, D0 = 1 channel 1 input, pin4 of connector CN3


‘1. on max cell voltage

‘2. on time

‘3. –ve delta V

‘4. cell temperature


next TCnt

let D1 = 0
let D0 = 0
gosub Convert

‘Get battery charging voltage

let Batt_V =AD
‘debud “charge”
if AD> BattV_Max then Batt_Chrg_Term

Chrg_Time = Chrg_Time + 1
If Chrg_Time > Chrg_Time_Max then Batt_Chrg_Term ‘Used maximum charge time
If AD < Batt_Peak then Batt_DeltaV
Let AD =AD +Neg_DeltaV
If AD <Batt_Peak then Batt_Chrg_Term

‘Detected negative deltaV in battery pack

**Insert battery pack temperature code here**
goto Chrg_Lp

‘Continue until charging terminated


Batt_Chrg_Term:
PWM Chrg_ Limit, 0.50

‘turn off charge current

Let Bat1_Chrg = 1

‘Indicate battery has been charged

Goto Main_Batt1


Convert:

ADC Interface Pins

-The LTC 1594 uses a four-pin interface, consisting of chip-select, clock data input and data output.
In this application, we tie the data lines together and connect to the PM104 pin designated DIO.
Here’s where the conversion occurs. The PM104 first sends the setup bits to the LTC1594, then
clocks in two bits followed by (sample time), one null bit (a dummy bit that always reads 0, followed
by the conversion data.

High CS1

‘ Deactivate the ADC to begin

High CLK

‘ Clock data on rising edge, so start with CLK high

High Dio
Pulsout CLK.2
Low DIO
Pulsout CLK.2
Let DIOp = D1

‘next bit of command

Pulseout CLK.2