Telex MCE325 User Manual

Page 51

Advertising
background image

4-13

12

Turn on the SPKR ON button. The meter should read –38 dBu or less. Turn off the SPKR ON
button.

NOTE

Noise measurements in the following steps were made using a 400 Hz to 30 kHz bandpass
filter with +40 dB of gain.

13

Turn on the MIC ON switch. Measure noise at U1 pin 1 (mic preamp out). The voltmeter
should read –26 dBu or less.

14

Turn on the PANEL MIC button. The meter should read –37 dBu or less.

15

Turn all buttons off.

16

Measure noise at U12 pin 7 (program A preamp out). The voltmeter should read –51 dBu or
less.

17

Measure noise at U12 pin 1 (program B preamp out). The voltmeter should read –51 dBu or
less.

18

Measure noise across intercom channels 1 through 4. All should measure –50 dBu or less.